Description
DC ev fuse ANL-B30SF51 automotive fuse
1. Dimensions (mm)
2. Specifications
Shell: Housing: Made of thermoplastic material (UL 94-V0, heat resistant) Visible fused components
Terminal: Copper alloy, gal. Sn 2 x M8 bolts, Distance 50.8 mm
Mounting Torque: 12.0 Nm +/- 1Nm
Breaking Capacity: 12V 24V 32V 48V 58V DC
Complies with: ISO 8820-5:2015, UL 248 Special Purpose Fuses
Operating Temperature Range: -40˚C to +125˚C (The maximum allowable temperature is 150°C at the contact point)
3. Time-Current Characteristics
| % of Rating | Opening Time Min / Max (s) | |
|---|---|---|
| 40A – 250A | 300A – 650A | |
| 75 | – / – | 14,400 / ∞ |
| 110 | 14,400 / ∞ | – / – |
| 135 | 120s / 1800s | – / – |
| 200 | 1s / 15s | 1s / 15s |
| 350 | 0.300s / 5s | 0.500s / 5s |
| 600 | 0.100s / 1s | 0.100s / 1s |
1: Short Circuit Protector only, Products in development – please contact GFEFUSE for more details regarding availability timing.
2: Voltage Drop measurements for short circuit protectors taken at 75% of rated current.
3: The typical I²t is an average value calculated from the breaking capacity tests by using the melting time before the arcing occurs.
4. Ratings
| TYPE | Rating Current (A) | Typ Voltage drop |
|---|---|---|
| ANL-B3040 | 40A | ≤110mV |
| ANL-B3050 | 50A | ≤110mV |
| ANL-B3060 | 60A | ≤110mV |
| ANL-B3070 | 70A | ≤110mV |
| ANL-B3080 | 80A | ≤110mV |
| ANL-B30100 | 100A | ≤110mV |
| ANL-B30125 | 125A | ≤110mV |
| ANL-B30150 | 150A | ≤110mV |
| ANL-B30175 | 175A | ≤110mV |
| ANL-B30200 | 200A | ≤110mV |
| ANL-B30225 | 225A | ≤110mV |
| ANL-B30250 | 250A | ≤80mV |
| ANL-B30275 | 275A | ≤80mV |
| ANL-B30300 | 300A | ≤80mV |
| ANL-B30350 | 350A | ≤80mV |
| ANL-B30400 | 400A | ≤80mV |
| ANL-B30450 | 450A | ≤80mV |
| ANL-B30500 | 500A | ≤80mV |
| ANL-B30550 | 550A | ≤80mV |
| ANL-B30600 | 600A | ≤80mV |
| ANL-B30650 | 650A | ≤80mV |