{"id":4226,"date":"2025-02-04T10:43:28","date_gmt":"2025-02-04T10:43:28","guid":{"rendered":"https:\/\/1clickrepair.in\/ESS\/?post_type=product&#038;p=4226"},"modified":"2026-10-28T10:35:06","modified_gmt":"2026-10-28T10:35:06","slug":"gfevt500-k-51e-high-speed-dc-fuse-500v","status":"publish","type":"product","link":"https:\/\/essfuse.com\/de\/product\/gfevt500-k-51e-high-speed-dc-fuse-500v\/","title":{"rendered":"High Speed DC Fuse\u2011GFEVT500\u2011K\u201151E Series Square\u2011Body Fuse,100A\u2011800A 500VDC,aR Class 50kA Breaking Capacity RoHS"},"content":{"rendered":"<p>GFEVT500-xxx KN-51E<br \/>\n<img decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/v7-upload.digoodcms.com\/website_193\/2025-07-08\/1-2.png?imageMogr2\/format\/webp\" \/><br \/>\nGFEVT500-xxx K-51E<br \/>\n<img decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/v7-upload.digoodcms.com\/website_193\/2025-07-08\/2-2.png?imageMogr2\/format\/webp\" \/><\/p>\n<div>\n<p><strong>GFEVT500\u2011K\u201151E Series High\u2011Speed Fuse<\/strong> is size\u20111# square\u2011body fast\u2011acting <strong>high speed dc fuse<\/strong> for new\u2011energy DC equipment backup short\u2011circuit protection. aR performance class, rating 100A\u2011800A 500VDC, max 50kA interrupting capacity, time constant \u22643\u202fms. Two variants: K\u2011type <strong>with fuse blow indicator<\/strong> and KN\u2011type without indicator. Features low I\u00b2t, low watt\u2011loss, superior cycling capability, high vibration\u2011resistance \u226520g acceleration. RoHS compliant, REACH declaration available upon request. Widely deployed for battery pack, energy\u2011storage systems and DC\u2011relay backup protection.<\/p>\n<p><a href=\"https:\/\/essfuse.com\/wp-content\/uploads\/2025\/02\/GFEVT500-K-51E-Series.-100-800A-500Vdc-fast-acting-fuse.pdf\">GFEVT500-K-51E-Series.-100-800A-500Vdc-fast-acting-fuse<\/a><\/p>\n<h2>Product At A Glance<\/h2>\n<table style=\"border: 1px solid #000; border-collapse: collapse; width: 100%;\">\n<thead>\n<tr>\n<th style=\"border: 1px solid #000; padding: 9px;\">Item<\/th>\n<th style=\"border: 1px solid #000; padding: 9px;\">Parameter<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Product Series<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u2011K\u201151E Series, Size\u20111# Square\u2011Body Fast\u2011Acting Fuse<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Current Range<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">100A\u2011800A<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Rated Voltage<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">500VDC<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Interrupting Capacity<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">50kA @500VDC; Minimum breaking current \u22653.0In<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Time Constant<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u22643\u202fms<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Performance Class<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">aR (Semiconductor \/ power\u2011device backup short\u2011circuit protection)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Variant Options<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">K\u2011type: with blow indicator; KN\u2011type: without blow indicator<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Standards Reference<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">UL 248.1, UL248.13; IEC 60269\u20111, IEC 60269\u20114<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Compliance<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">RoHS compliant, REACH declaration available upon request<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Model\u2011Specific Electrical Data @50kA 500VDC<\/h2>\n<table style=\"border: 1px solid #000; border-collapse: collapse; width: 100%;\">\n<thead>\n<tr>\n<th style=\"border: 1px solid #000; padding: 9px;\">Part Number<\/th>\n<th style=\"border: 1px solid #000; padding: 9px;\">Rated Amps<\/th>\n<th style=\"border: 1px solid #000; padding: 9px;\">Melting A\u00b2s<\/th>\n<th style=\"border: 1px solid #000; padding: 9px;\">Clearing A\u00b2s<\/th>\n<th style=\"border: 1px solid #000; padding: 9px;\">100% Power Loss(W)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u2011100K\u201151E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">100A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">820<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">7370<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">23<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u2011125K\u201151E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">125A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">1340<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">11910<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">28<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u2011160K\u201151E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">160A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">2410<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">21550<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">35<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u2011200K\u201151E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">200A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">3030<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">26910<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">38<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u2011250K\u201151E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">250A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">5050<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">45680<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">52<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u2011275K\u201151E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">275A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">6140<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">59220<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">55<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u2011315K\u201151E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">315A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">7910<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">75060<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">64<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u2011350K\u201151E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">350A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">10520<\/td>\n<td><\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">68<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u2011400K\u201151E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">400A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">15060<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">143820<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">72<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u2011450K\u201151E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">450A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">20830<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">205160<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">78<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u2011500K\u201151E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">500A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">26760<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">264150<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">87<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u2011550K\u201151E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">550A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">36520<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">363150<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">92<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u2011630K\u201151E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">630A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">53800<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">554220<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">100<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u2011700K\u201151E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">700A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">71550<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">742770<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">102<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u2011800K\u201151E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">800A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">99540<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">1035000<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">113<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Key Features &amp; Benefits<\/h2>\n<ul>\n<li>aR\u2011class square\u2011body fast\u2011acting DC fuse, low\u2011I\u00b2t characteristic, excellent current\u2011limiting performance for semiconductor\u2011device backup short\u2011circuit protection<\/li>\n<li>High interrupting\u2011capacity:50kA @500VDC; time constant \u22643\u202fms, minimum breaking current \u22653.0In<\/li>\n<li>Two mechanical options: K\u2011type with fuse blow indicator; KN\u2011type without indicator for cost\u2011optimized projects<\/li>\n<li>Low watt\u2011loss design, superior cycling\u2011capability, wide temperature tolerance, vibration\u2011resistance \u226520g acceleration<\/li>\n<li>Supports full derating corrections for high\u2011temperature, high\u2011altitude and forced\u2011air\u2011cooling operating\u2011conditions<\/li>\n<li>Complies with UL248.1\u201113 &amp; IEC60269\u20111\u20114; RoHS compliant, REACH documents available for export\u2011oriented projects<\/li>\n<\/ul>\n<h2>Application Overview<\/h2>\n<p>GFEVT500\u2011K\u201151E series square\u2011body high\u2011speed fuses serve as short\u2011circuit backup\u2011protection for heavy\u2011duty new\u2011energy DC\u2011equipment. Mainly deployed for battery\u2011pack protection, energy\u2011storage power\u2011systems and DC\u2011relay backup\u2011protection.<\/p>\n<p><strong>Critical Tip:<\/strong> Long\u2011term continuous operating\u2011current shall \u226475% of fuse rated\u2011current. Apply temperature\u2011altitude derating\u2011factors for enclosed\u2011cabinet installation. Always disconnect power before fuse replacement.<\/p>\n<h2>Installation &amp; Operating Notes<\/h2>\n<ol>\n<li>Match copper\u2011cable cross\u2011section in accordance with datasheet table to guarantee stable contact performance.<\/li>\n<li>Long\u2011term continuous working\u2011current cannot exceed 75% of nominal fuse ampere\u2011rating.<\/li>\n<li>Implement current\u2011derating when ambient\u2011temperature\uff1e40\u2103 or installation\u2011altitude\uff1e2000\u202fm in closed\u2011cabinet environment.<\/li>\n<li>Mounting can be vertical, horizontal or inclined; avoid gravity\u2011vibration interference for spring\u2011contact construction.<\/li>\n<li>Replace fuse immediately if mechanical\u2011damage occurs; avoid live\u2011load fuse\u2011replacement unless equipment design explicitly permits.<\/li>\n<\/ol>\n<h2>Typical Applications<\/h2>\n<ul>\n<li>New\u2011energy battery\u2011pack over\u2011current and short\u2011circuit backup\u2011protection<\/li>\n<li>BESS energy\u2011storage system DC\u2011feeder protection<\/li>\n<li>DC\u2011relay and power\u2011semiconductor device backup short\u2011circuit\u2011protection<\/li>\n<li>Heavy\u2011duty industrial 500VDC power\u2011distribution equipment<\/li>\n<li>New\u2011energy converter\u2011inverter internal DC\u2011side protection<\/li>\n<\/ul>\n<p>Pair GFEVT500\u2011K\u201151E series fuse with our <a href=\"https:\/\/essfuse.com\/de\/product-category\/fuse\u2011holders\/\">matching heavy\u2011duty semiconductor fuse holders<\/a> for a complete heavy\u2011current DC\u2011protection assembly.<\/p>\n<h2>Safety Reminders<\/h2>\n<ul>\n<li>Disconnect all DC\u2011power before servicing or changing fuses. <strong>Strictly prohibit live\u2011line 500VDC high\u2011voltage operation.<\/strong><\/li>\n<li>Follow 75% rated\u2011current continuous\u2011working derating\u2011rule; extra\u2011derating required for high\u2011temperature \/ high\u2011altitude closed\u2011cabinet installation.<\/li>\n<li>Select fuse breaking\u2011capacity higher than prospective short\u2011circuit\u2011current of your system.<\/li>\n<li>Refer to official datasheet for I\u2011t curve, derating\u2011curves and dimension drawings before bulk\u2011procurement.<\/li>\n<li>Any mechanically\u2011damaged fuse\u2011unit must be discarded and replaced immediately.<\/li>\n<\/ul>\n<h2>H\u00e4ufig gestellte Fragen<\/h2>\n<p><strong>Q: What is GFEVT500\u2011K\u201151E series high\u2011speed fuse?<\/strong><br \/>\nA: GFEVT500\u2011K\u201151E is size\u20111# square\u2011body aR\u2011class fast\u2011acting DC fuse, rating 100A\u2011800A @500VDC, 50kA interrupting\u2011capacity. Two variants K (with indicator) \/ KN (no indicator). Used for battery\u2011pack and energy\u2011storage backup\u2011protection, RoHS compliant, REACH available upon request.<\/p>\n<p><strong>Q: What is the continuous\u2011current usage rule?<\/strong><br \/>\nA: Long\u2011term operating\u2011current must be \u226475% of fuse rated\u2011current. Additional derating needed for high\u2011temperature and high\u2011altitude enclosed\u2011cabinet applications.<\/p>\n<p><strong>Q: What variants are available for this series?<\/strong><br \/>\nA: K\u2011type: with fuse blow\u2011out indicator; KN\u2011type: without indicator for cost\u2011sensitive projects.<\/p>\n<p><strong>Q: What standards does this series comply with?<\/strong><br \/>\nA: Reference standards UL 248.1, UL248.13, IEC 60269\u20111, IEC 60269\u20114; RoHS compliant, REACH declaration can be provided for overseas\u2011export\u2011projects.<\/p>\n<p><strong>Q: Where is GFEVT500\u2011K\u201151E mainly applied?<\/strong><br \/>\nA: For battery\u2011pack protection, BESS energy\u2011storage cabinets, DC\u2011relay backup\u2011protection and heavy\u2011duty 500VDC new\u2011energy converter\u2011inverter DC\u2011side circuits.<\/p>\n<h2>Request Quotation &amp; Technical Support<\/h2>\n<p>Please provide target part\u2011number(K\u2011type or KN\u2011type), order\u2011quantity, system short\u2011circuit\u2011current, ambient\u2011temperature and altitude\u2011conditions. Our engineering\u2011team can deliver full datasheet, bulk\u2011price quotation and component\u2011selection\u2011guidance for battery\u2011energy\u2011storage DC\u2011protection\u2011projects.<\/p>\n<p style=\"font\u2011size: 0.9em; color: #555;\">GFEVT500\u2011K\u201151E Series High\u2011Speed Fuse \u00b7 EssFuse. Confirm datasheet I\u2011t, derating and dimension specs before mass\u2011production.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<pre><code>GFEVT500\u2011K\u201151E series high\u2011speed square\u2011body DC fuse,100A\u2011800A 500VDC,aR\u2011class 50kA breaking capacity, RoHS REACH for battery &amp; energy\u2011storage short\u2011circuit backup protection.\r\n<\/code><\/pre>","protected":false},"featured_media":16315,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[139],"product_tag":[],"class_list":["post-4226","product","type-product","status-publish","has-post-thumbnail","product_cat-square-high-speed-fuse","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/essfuse.com\/de\/wp-json\/wp\/v2\/product\/4226","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/essfuse.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/essfuse.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/essfuse.com\/de\/wp-json\/wp\/v2\/comments?post=4226"}],"version-history":[{"count":3,"href":"https:\/\/essfuse.com\/de\/wp-json\/wp\/v2\/product\/4226\/revisions"}],"predecessor-version":[{"id":16313,"href":"https:\/\/essfuse.com\/de\/wp-json\/wp\/v2\/product\/4226\/revisions\/16313"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/essfuse.com\/de\/wp-json\/wp\/v2\/media\/16315"}],"wp:attachment":[{"href":"https:\/\/essfuse.com\/de\/wp-json\/wp\/v2\/media?parent=4226"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/essfuse.com\/de\/wp-json\/wp\/v2\/product_brand?post=4226"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/essfuse.com\/de\/wp-json\/wp\/v2\/product_cat?post=4226"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/essfuse.com\/de\/wp-json\/wp\/v2\/product_tag?post=4226"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}