{"id":4130,"date":"2025-10-21T17:03:59","date_gmt":"2025-10-21T17:03:59","guid":{"rendered":"https:\/\/1clickrepair.in\/ESS\/?post_type=product&#038;p=4130"},"modified":"2026-10-28T23:15:53","modified_gmt":"2026-10-28T23:15:53","slug":"gfevt1500-159e-square-high-speed-fuses-1400a-3000a-1500v-new-energy-fuse","status":"publish","type":"product","link":"https:\/\/essfuse.com\/en_au\/product\/gfevt1500-159e-square-high-speed-fuses-1400a-3000a-1500v-new-energy-fuse\/","title":{"rendered":"High-Speed Fuses GFEVT1500\u2011159E 1400\u20113000A 1500VDC Fuse"},"content":{"rendered":"<p>Dimensions (mm)<\/p>\n<p><img decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/v7-upload.digoodcms.com\/website_193\/2025-05-30\/20250328110639105.png?imageMogr2\/format\/webp\" \/><\/p>\n<h2>GFEVT1500\u2011159E Square High\u2011Speed Fuses 1400\u20113000A 1500VDC Fast\u2011Acting New\u2011Energy Fuse<\/h2>\n<pre><code>Our High-Speed Fuses model GFEVT1500\u2011159E is a square fast-acting DC fuse rated 1500Vdc, covering 1400A to 3000A. This high-speed fuse provides 250kA high interrupting capacity, UL248-13 certified, widely used for energy storage ESS containers, large battery packs and new energy DC overcurrent &amp; short circuit protection.\r\n<\/code><\/pre>\n<p>GFEVT1500\u2011159E series square\u2011body high\u2011speed fast\u2011acting DC fuses are engineered for 1500Vdc new\u2011energy power systems with rated current from <strong>1400A\u20113000A<\/strong>. Excellent DC interrupting performance provides reliable short\u2011circuit protection for energy storage containers, battery packs, DC combiner cabinets and power converters. UL 248\u201113 listed and RoHS compliant, superior cycling capability for heavy\u2011duty DC working conditions.<\/p>\n<h2>Main Electrical Ratings &amp; Key Specifications<\/h2>\n<table style=\"width: 100%; border-collapse: collapse; margin: 18px 0;\">\n<tbody>\n<tr>\n<th style=\"border: 1px solid #000; padding: 12px; background: #f3f4f6; text-align: left;\">Item<\/th>\n<th style=\"border: 1px solid #000; padding: 12px; text-align: left;\">Parameter<\/th>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 12px;\">Rated Voltage<\/td>\n<td style=\"border: 1px solid #000; padding: 12px;\">1500 Vdc<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 12px;\">Rated Current Range<\/td>\n<td style=\"border: 1px solid #000; padding: 12px;\">1400A ~ 3000A<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 12px;\">Interrupting Capacity<\/td>\n<td style=\"border: 1px solid #000; padding: 12px;\">250kA@1500Vdc (L\/R \u22645ms)<br \/>\n100kA@1500Vdc (L\/R \u226415ms)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 12px;\">Fuse Characteristic<\/td>\n<td style=\"border: 1px solid #000; padding: 12px;\">Fast\u2011Acting High\u2011Speed DC Fuse<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 12px;\">Certifications<\/td>\n<td style=\"border: 1px solid #000; padding: 12px;\">UL248\u201113 Listed, RoHS Compliant, REACH statement upon request<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 12px;\">Operating Temperature<\/td>\n<td style=\"border: 1px solid #000; padding: 12px;\">\u201140\u2103 ~ +85\u2103; Standard working:\u20115\u2103 ~ +40\u2103<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 12px;\">Storage Condition<\/td>\n<td style=\"border: 1px solid #000; padding: 12px;\">\u201140\u2103 ~ +85\u2103; RH \u226470% @40\u2103<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 12px;\">Mounting Requirement<\/td>\n<td style=\"border: 1px solid #000; padding: 12px;\">5 pcs M12 screws each side; Nut torque: 35\u00b14% N\u00b7m<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 12px;\">Application Scenarios<\/td>\n<td style=\"border: 1px solid #000; padding: 12px;\">Energy Storage ESS, Battery Pack, DC Converter, New\u2011Energy Power Equipment Short\u2011circuit Protection<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Model List | Pre\u2011Arcing I\u00b2t &amp; Power Loss Data<\/h2>\n<table style=\"width: 100%; border-collapse: collapse; margin: 18px 0;\">\n<tbody>\n<tr>\n<th style=\"border: 1px solid #000; padding: 10px; background: #f3f4f6;\">Part Number<\/th>\n<th style=\"border: 1px solid #000; padding: 10px; background: #f3f4f6;\">Rated Amps<\/th>\n<th style=\"border: 1px solid #000; padding: 10px; background: #f3f4f6;\">Pre\u2011Arcing I\u00b2t(A\u00b2s)<\/th>\n<th style=\"border: 1px solid #000; padding: 10px; background: #f3f4f6;\">Max Operating I\u00b2t(A\u00b2s)<\/th>\n<th style=\"border: 1px solid #000; padding: 10px; background: #f3f4f6;\">Power Loss(W)<\/th>\n<th style=\"border: 1px solid #000; padding: 10px; background: #f3f4f6;\">Compliance<\/th>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 10px;\">GFEVT1500\u20111400A\u2011159E<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">1400A<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">833,250<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">3,024,000<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">350<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">RoHS<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 10px;\">GFEVT1500\u20111500A\u2011159E<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">1500A<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">1,078,000<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">3,759,500<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">370<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">RoHS<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 10px;\">GFEVT1500\u20111600A\u2011159E<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">1600A<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">1,325,700<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">5,435,000<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">420<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">RoHS<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 10px;\">GFEVT1500\u20111800A\u2011159E<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">1800A<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">1,980,000<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">5,750,000<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">460<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">RoHS<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 10px;\">GFEVT1500\u20112000A\u2011159E<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">2000A<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">2,530,000<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">7,910,000<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">475<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">RoHS<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 10px;\">GFEVT1500\u20112500A\u2011159E<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">2500A<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">4,696,500<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">14,294,000<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">520<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">RoHS<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 10px;\">GFEVT1500\u20113000A\u2011159E<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">3000A<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">8,505,000<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">25,029,000<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">590<\/td>\n<td style=\"border: 1px solid #000; padding: 10px;\">RoHS<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Mechanical Dimension<\/h2>\n<p>Square housing structure, nominal width 159mm, max 163mm. Each side fitted with 5pcs M12 mounting holes; Hole max depth:13mm, minimum thread length:10mm. Terminals tin\u2011plated 3\u20115\u03bcm. Refer to dimension drawing for full mechanical dimension details.<\/p>\n<h2>Derating &amp; Installation Instructions<\/h2>\n<ul>\n<li>Recommended continuous working current \u226475% of fuse rated\u2011current under standard environment.<\/li>\n<li>When ambient temperature higher than 40\u2103, apply temperature derating factor Kt. For closed cabinet high\u2011altitude installation 2000\u20114500m, apply altitude factor Ka, derate 2\u20115% per 1000\u2011meter elevation.<\/li>\n<li>M12 mounting nut recommended tightening torque: <strong>35\u00b14% N\u00b7m<\/strong>.<\/li>\n<li>Support vertical, horizontal and inclined installation; prevent gravity and vibration influence for spring\u2011contact assembly.<\/li>\n<\/ul>\n<h2>Typical Applications<\/h2>\n<ul>\n<li>Energy\u2011storage container &amp; ESS DC main circuit protection<\/li>\n<li>Large\u2011capacity battery pack short\u2011circuit protection<\/li>\n<li>1500Vdc power converter over\u2011current protection<\/li>\n<li>New\u2011energy power station high\u2011current DC protection<\/li>\n<\/ul>\n<h2>Download Datasheet<\/h2>\n<p><a href=\"https:\/\/essfuse.com\/wp-content\/uploads\/2025\/10\/GFHVT1500-159E-Series.-1400-3000A-1500Vdc-Fast-Acting-Fuse-1.pdf\">GFHVT1500-159E-Series.-1400-3000A-1500Vdc-Fast-Acting-Fuse-1<\/a><\/p>\n<h2>Frequently Asked Questions<\/h2>\n<dl>\n<dt><strong>What is the rated voltage of GFEVT1500\u2011159E series fuse?<\/strong><\/dt>\n<dd>This series is rated for <strong>1500Vdc<\/strong>, designed exclusively for DC new\u2011energy systems, not recommended for AC application.<\/dd>\n<\/dl>\n<p>&nbsp;<\/p>\n<dl>\n<dt><strong>What current range does GFEVT1500\u2011159E cover?<\/strong><\/dt>\n<dd>Available rated current: 1400A,1500A,1600A,1800A,2000A,2500A,3000A.<\/dd>\n<\/dl>\n<p>&nbsp;<\/p>\n<dl>\n<dt><strong>What is the interrupting capacity?<\/strong><\/dt>\n<dd>250kA@1500Vdc (L\/R \u22645ms); 100kA@1500Vdc (L\/R \u226415ms).<\/dd>\n<\/dl>\n<p>&nbsp;<\/p>\n<dl>\n<dt><strong>What certifications does this fuse have?<\/strong><\/dt>\n<dd>UL Listed to UL248\u201113 standard, RoHS compliant. REACH declaration available upon customer request.<\/dd>\n<\/dl>\n<p>&nbsp;<\/p>\n<dl>\n<dt><strong>What continuous current should I use for selection?<\/strong><\/dt>\n<dd>General rule: continuous operating current \u2264 <strong>75% of fuse rated current<\/strong> under standard \u20115\u2103~40\u2103 ambient condition.<\/dd>\n<\/dl>\n<p>&nbsp;<\/p>\n<dl>\n<dt><strong>Do I need derating for high\u2011temperature or high\u2011altitude installation?<\/strong><\/dt>\n<dd>Yes. Above 40\u2103 ambient temperature needs temperature derating factor Kt. For closed\u2011box installation between 2000\u20114500\u202fm altitude, derate rated\u2011current 2\u20115% per 1000\u202fm rise. Open\u2011air installation can ignore altitude influence generally.<\/dd>\n<\/dl>\n<p>&nbsp;<\/p>\n<dl>\n<dt><strong>What is the correct tightening torque for M12 mounting screws?<\/strong><\/dt>\n<dd>Recommended nut tightening torque: <strong>35\u00b14% N\u00b7m<\/strong>. Improper torque will cause overheating and higher power loss.<\/dd>\n<\/dl>\n<p>&nbsp;<\/p>\n<dl>\n<dt><strong>Can this fuse be installed horizontally or vertically?<\/strong><\/dt>\n<dd>Yes, supports vertical, horizontal and inclined mounting. Avoid gravity &amp; vibration impact for spring\u2011contact connections.<\/dd>\n<\/dl>\n<p>&nbsp;<\/p>\n<dl>\n<dt><strong>What applications fit for GFEVT1500\u2011159E high\u2011speed fuse?<\/strong><\/dt>\n<dd>Energy storage ESS container, large battery pack, DC combiner cabinet, 1500Vdc converter, new\u2011energy power station DC short\u2011circuit &amp; over\u2011current protection.<\/dd>\n<\/dl>\n<p>&nbsp;<\/p>\n<dl>\n<dt><strong>Can I replace the fuse under load condition?<\/strong><\/dt>\n<dd>NOT recommended. Do not replace fuse with live\u2011load unless matched fuse\u2011disconnector switch assembly is applied.<\/dd>\n<\/dl>\n<p>&nbsp;<\/p>\n<dl>\n<dt><strong>What is storage requirement?<\/strong><\/dt>\n<dd>Store in original package: \u201140\u2103 ~ +85\u2103, max RH 70% at 40\u2103, dust\u2011free warehouse environment.<\/dd>\n<\/dl>","protected":false},"excerpt":{"rendered":"<pre><code>GFEVT1500\u2011159E square high-speed 1500Vdc fuse, 1400\u20113000A fast-acting DC fuse, 250kA interrupt rating, UL248-13 listed for energy storage, ESS and battery pack short circuit protection.\r\n<\/code><\/pre>\n<pre><code>\r\n<\/code><\/pre>","protected":false},"featured_media":16340,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[139],"product_tag":[],"class_list":["post-4130","product","type-product","status-publish","has-post-thumbnail","product_cat-square-high-speed-fuse","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/essfuse.com\/en_au\/wp-json\/wp\/v2\/product\/4130","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/essfuse.com\/en_au\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/essfuse.com\/en_au\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/essfuse.com\/en_au\/wp-json\/wp\/v2\/comments?post=4130"}],"version-history":[{"count":3,"href":"https:\/\/essfuse.com\/en_au\/wp-json\/wp\/v2\/product\/4130\/revisions"}],"predecessor-version":[{"id":16338,"href":"https:\/\/essfuse.com\/en_au\/wp-json\/wp\/v2\/product\/4130\/revisions\/16338"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/essfuse.com\/en_au\/wp-json\/wp\/v2\/media\/16340"}],"wp:attachment":[{"href":"https:\/\/essfuse.com\/en_au\/wp-json\/wp\/v2\/media?parent=4130"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/essfuse.com\/en_au\/wp-json\/wp\/v2\/product_brand?post=4130"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/essfuse.com\/en_au\/wp-json\/wp\/v2\/product_cat?post=4130"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/essfuse.com\/en_au\/wp-json\/wp\/v2\/product_tag?post=4130"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}