EssEv‑0# Series Square‑Body aR Fast‑Acting ESS DC Fuse 1500VDC 50‑200A
EssEv‑0# square‑body aR fast‑acting DC fuse, 1500VDC 50‑200A,100kA breaking capacity for energy‑storage,battery‑pack and DC relay backup protection.
¿Necesitas un fusible para tu proyecto?
Comparta con nosotros sus requisitos para obtener asesoramiento sobre productos y un presupuesto.
EssEv‑0# Series Square‑Body aR Fast‑Acting ESS DC Fuse 1500VDC 50‑200A
EssEv‑0# Series Square‑Body aR Fast‑Acting ESS DC Fuse 1500VDC 50‑200A is 0# size square‑body high‑speed aR‑class DC fuse for energy‑storage and new‑energy DC systems. Rated voltage 1500VDC, max interrupting capacity 100kA@1500VDC(L/R:10‑15ms), minimum breaking current>3In. Features ultra‑fast fault‑current interruption, excellent vibration & shock resistance ≥20g, compact square‑body construction. Referenced to UL‑248‑1/UL‑248‑13, IEC 60269‑1/IEC 60269‑4, RoHS compliant. Ideal for energy‑storage cabinet, battery‑pack and DC relay backup short‑circuit protection.
ESSEV-Series.-0.-50-200A-1500Vdc-IR-100kA-2
Características principales
- Model Series: EssEv‑0# Square‑Body aR Fast‑Acting ESS DC Fuse
- Rated Voltage: 1500 VDC
- Current Range: 50A‑200A, Operation Class: aR (semiconductor short‑circuit protection)
- Max Breaking Capacity:100kA @1500VDC (L/R:10‑15ms)
- Minimum Breaking Current:>3 In
- Ultra‑fast opening response under heavy DC fault‑current conditions
- Compact 0# square‑body footprint for cabinet layout optimization
- Excellent anti‑voltaic impingement, wide ambient temperature tolerance
- High mechanical shock & vibration resistance ≥20g
- Compliant: Referenced to UL‑248‑1/UL‑248‑13, IEC 60269‑1/IEC 60269‑4, RoHS; REACH available upon request
General Technical Specifications
| Product Series | EssEv‑0# Series Square‑Body aR Fast‑Acting ESS DC Fuse |
| Tensión nominal | 1500 V DC |
| Rango de corriente nominal | 50A‑200A (aR operation class) |
| Max Breaking Capacity | 100kA @1500VDC (L/R:10‑15ms) |
| Minimum Breaking Current | >3 In |
| Body Size | 0# square‑body mounting type |
| Vibration Resistance | ≥20g |
| Standards Compliance | Referenced to UL‑248‑1/UL‑248‑13, IEC60269‑1/IEC60269‑4, RoHS |
| Temperatura de funcionamiento | ‑5℃ ~ +40℃(regular);‑40℃~+85℃(allowable) |
| Temperatura de almacenamiento | ‑40℃ ~ +120℃ |
Part Number List & Electrical Parameters(Test@1500VDC,100kA,L/R=12.5ms)
| Número de pieza | Corriente nominal | Melting A²s | Clearing A²s | Power Loss‑50%In(W) | Power Loss‑100%In(W) |
| EssEv‑50A | 50A | 330 | 1780 | 3.5 | 14.0 |
| EssEv‑63A | 63A | 570 | 3000 | 3.8 | 18.0 |
| EssEv‑80A | 80A | 985 | 5345 | 4.5 | 24.5 |
| EssEv‑100A | 100A | 1600 | 8600 | 5.6 | 31.0 |
| EssEv‑125A | 125A | 2880 | 15360 | 6.8 | 40.0 |
| EssEv‑150A | 150A | 5460 | 28930 | 8.0 | 48.0 |
| EssEv‑160A | 160A | 5850 | 33800 | 9.5 | 58.0 |
| EssEv‑175A | 175A | 6695 | 36500 | 10.5 | 68.0 |
| EssEv‑200A | 200A | 8800 | 47560 | 12.0 | 77.0 |
Application Scenarios
EssEv‑0# Series Square‑Body aR Fast‑Acting ESS DC Fuse 1500VDC 50‑200A applies to new‑energy DC‑system projects: energy‑storage power station cabinets, energy‑storage battery‑pack protection, DC relay backup protection. The aR‑class high‑speed characteristic provides reliable short‑circuit protection for power semiconductors and DC components under heavy fault‑current conditions.
Installation & Operating Notes
- Square‑body mounting design; ensure good bolt contact to avoid poor contact and over‑heating risk.
- Recommended continuous operating current ≤75% of fuse rated‑current; apply temperature‑derating factor Kt when ambient temperature>40℃.
- Altitude ≤2000m: no‑derating; for closed‑box installation within 2000‑4500m: derate 2%‑5% per 1000m elevation increase. Open‑air installation can normally ignore altitude influence; Insulation clearance needs re‑checking at high altitude, refer to GB/T16935.1.
- Supports vertical, horizontal and inclined mounting; for spring‑contact‑type fuses, prevent adverse gravity‑vibration influence on electrical contact.
- Forced air cooling can improve heat dissipation and increase allowable current, refer to Kv correction coefficient.
- Do NOT replace fuse under live DC load unless equipped with certified load‑break switchgear.
- Replace fuse immediately if mechanical damage, crack or deformation occurs on fuse body.
- Additional reliability validation test shall be conducted for extremely high‑vibration working environments.
- Select matched copper conductor cross‑section for terminals to control temperature‑rise performance.
Packing & Storage Requirements
Standard original‑box bulk package. Storage temperature:‑40℃~+120℃; humidity limit: RH≤70%@40℃, RH≤80%@30℃, RH≤90%@20℃. Sample testing support, OEM customization, stable mass‑volume supply for energy‑‑storage equipment manufacturers. REACH declaration available upon customer request.
Preguntas frecuentes
Q: What rating for EssEv‑0# Series Square‑Body aR Fast‑Acting ESS DC Fuse 1500VDC 50‑200A?
A: Rated 1500VDC, current range 50‑200A, aR‑class, max breaking capacity 100kA@1500VDC(L/R:10‑15ms), min breaking current>3In.
Q: What is aR‑class fuse?
A: aR‑class is semiconductor‑protecting high‑speed fuse class, designed for fast short‑circuit protection of power semiconductor devices.
Q: What is the body style of EssEv‑0# series?
A: Compact 0# square‑body mounting construction for energy‑‑storage cabinet installation.
Q: What standards does EssEv‑0# comply with?
A: Referenced to UL‑248‑1/UL‑248‑13, IEC60269‑1/IEC60269‑4, RoHS compliant; REACH document available on request.
Q: Main application scenarios for EssEv‑0# series?
A: Energy‑‑storage cabinet, battery‑pack and DC relay backup semiconductor short‑circuit protection.




