{"id":16477,"date":"2026-10-29T23:18:30","date_gmt":"2026-10-29T23:18:30","guid":{"rendered":"https:\/\/essfuse.com\/?post_type=product&#038;p=16477"},"modified":"2026-10-29T23:43:52","modified_gmt":"2026-10-29T23:43:52","slug":"gfevt1000-38r-ev-dc-fuse-250a-400a-1000v-dc-ar-high-speed-fuse","status":"publish","type":"product","link":"https:\/\/essfuse.com\/fr\/produit\/gfevt1000-38r-ev-dc-fuse-250a-400a-1000v-dc-ar-high-speed-fuse\/","title":{"rendered":"GFEVT1000\u201138R EV DC Fuse | 250A\u2011400A 1000V DC aR High\u2011Speed Fuse"},"content":{"rendered":"<p><!-- \u5f00\u7bc7\u4e13\u4e1a\u6b63\u6587 --><\/p>\n<p><strong>GFEVT1000\u201138R ev dc fuse<\/strong> is aR\u2011class high\u2011speed bolt\u2011mount DC fuse dedicated for energy\u2011storage systems and EV battery\u2011pack protection. Rated 250A\u2011400A at 1000V DC with 50kA high breaking capacity and time\u2011constant \u22645\u202fms. It uses M8 mounting bolt with recommended installation torque 12\u00b11.0\u202fN.m. The fuse supports parallel installation for higher ampacity within dimensional guidelines. It delivers superior anti\u2011shock &amp; anti\u2011vibration performance \u226520g acceleration. For high\u2011altitude applications between 2000\u20114500\u202fm, derating for rated\u2011current and insulation distance correction shall be considered. Manufactured to IEC60269.4, UL248\u201113, JASO\u2011D622 standards, CE marked, RoHS\u2011compliant, REACH declaration available upon request.<\/p>\n<p><!-- \u603b\u89c4\u683c\u5b9e\u7ebf\u8868\u683c --><\/p>\n<table style=\"width: 100%; border-collapse: collapse; margin: 20px 0;\" border=\"1\" cellspacing=\"0\" cellpadding=\"8\">\n<tbody>\n<tr>\n<td><strong>Series Model<\/strong><\/td>\n<td>GFEVT1000\u201138R High\u2011Speed EV &amp; Energy\u2011Storage DC Fuse<\/td>\n<\/tr>\n<tr>\n<td><strong>Fuse Category<\/strong><\/td>\n<td>aR High\u2011speed DC protection fuse<\/td>\n<\/tr>\n<tr>\n<td><strong>Rated DC Voltage<\/strong><\/td>\n<td>1000V DC<\/td>\n<\/tr>\n<tr>\n<td><strong>Rated Current Range<\/strong><\/td>\n<td>250A\u2011400A<\/td>\n<\/tr>\n<tr>\n<td><strong>Rated Breaking Capacity<\/strong><\/td>\n<td>50\u202fkA @1000V DC<\/td>\n<\/tr>\n<tr>\n<td><strong>Time Constant<\/strong><\/td>\n<td>\u22645\u202fms<\/td>\n<\/tr>\n<tr>\n<td><strong>Mounting Spec<\/strong><\/td>\n<td>M8 bolt, installation torque:12\u00b11.0\u202fN.m<\/td>\n<\/tr>\n<tr>\n<td><strong>Compliance &amp; Certifications<\/strong><\/td>\n<td>IEC60269\u20114, UL248\u201113, JASO\u2011D622; CE; RoHS; REACH upon request<\/td>\n<\/tr>\n<tr>\n<td><strong>Anti\u2011Vibration Capacity<\/strong><\/td>\n<td>\u226520g high\u2011frequency vibration resistance<\/td>\n<\/tr>\n<tr>\n<td><strong>Standard Altitude<\/strong><\/td>\n<td>\u22642000\u202fm; 2000\u20114500\u202fm requires current derating &amp; insulation correction<\/td>\n<\/tr>\n<tr>\n<td><strong>Typical Applications<\/strong><\/td>\n<td>Energy\u2011storage system, EV \/ HEV high\u2011voltage battery\u2011pack DC over\u2011current &amp; short\u2011circuit protection<\/td>\n<\/tr>\n<tr>\n<td><strong>Special Feature<\/strong><\/td>\n<td>Support parallel installation for increased ampacity; low watt\u2011loss; excellent DC interrupting performance<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><!-- \u578b\u53f7\u53c2\u6570\u5b9e\u7ebf\u8868\u683c --><\/p>\n<table style=\"width: 100%; border-collapse: collapse; margin: 20px 0;\" border=\"1\" cellspacing=\"0\" cellpadding=\"8\">\n<thead>\n<tr>\n<th>Part Number<\/th>\n<th>Rated Current(A)<\/th>\n<th>Melting I\u00b2t(A\u00b2s) \u2264<\/th>\n<th>Clearing I\u00b2t(A\u00b2s) @50kA\/1000Vdc<\/th>\n<th>100% Watts Loss(W)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>GFEVT1000\u2011250A\u201138R<\/td>\n<td>250<\/td>\n<td>10560<\/td>\n<td>48900<\/td>\n<td>49<\/td>\n<\/tr>\n<tr>\n<td>GFEVT1000\u2011275A\u201138R<\/td>\n<td>275<\/td>\n<td>12900<\/td>\n<td>60090<\/td>\n<td>67<\/td>\n<\/tr>\n<tr>\n<td>GFEVT1000\u2011315A\u201138R<\/td>\n<td>315<\/td>\n<td>15600<\/td>\n<td>72600<\/td>\n<td>90<\/td>\n<\/tr>\n<tr>\n<td>GFEVT1000\u2011350A\u201138R<\/td>\n<td>350<\/td>\n<td>20800<\/td>\n<td>93000<\/td>\n<td>105<\/td>\n<\/tr>\n<tr>\n<td>GFEVT1000\u2011400A\u201138R<\/td>\n<td>400<\/td>\n<td>38500<\/td>\n<td>130200<\/td>\n<td>130<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><!-- FAQ\u53ef\u89c6\u5316\u95ee\u7b54\u533a\u5757 --><\/p>\n<div style=\"margin: 30px 0;\">\n<h3>Frequently Asked Questions<\/h3>\n<div style=\"border: 1px solid #ddd; margin-bottom: 8px;\">\n<div style=\"background: #f7f7f7; padding: 12px 16px; font-weight: bold;\">Q: What fuse class is GFEVT1000\u201138R ev dc fuse?<\/div>\n<div style=\"padding: 12px 16px;\">A: GFEVT1000\u201138R belongs to aR high\u2011speed DC fuse, specially designed for energy\u2011storage and EV battery\u2011pack short\u2011circuit &amp; over\u2011current protection.<\/div>\n<\/div>\n<div style=\"border: 1px solid #ddd; margin-bottom: 8px;\">\n<div style=\"background: #f7f7f7; padding: 12px 16px; font-weight: bold;\">Q: What is breaking\u2011capacity and time\u2011constant of GFEVT1000\u201138R?<\/div>\n<div style=\"padding: 12px 16px;\">A: Rated interrupting capacity is 50kA at 1000V DC; time\u2011constant \u22645\u202fms for fast fault clearing for high\u2011power DC systems.<\/div>\n<\/div>\n<div style=\"border: 1px solid #ddd; margin-bottom: 8px;\">\n<div style=\"background: #f7f7f7; padding: 12px 16px; font-weight: bold;\">Q: What mounting requirement for GFEVT1000\u201138R?<\/div>\n<div style=\"padding: 12px 16px;\">A: M8 bolt\u2011on installation; recommended tightening torque 12\u00b11.0\u202fN.m to guarantee stable electrical contact.<\/div>\n<\/div>\n<div style=\"border: 1px solid #ddd; margin-bottom: 8px;\">\n<div style=\"background: #f7f7f7; padding: 12px 16px; font-weight: bold;\">Q: Does GFEVT1000\u201138R work at high altitude above 2000\u202fm?<\/div>\n<div style=\"padding: 12px 16px;\">A: For altitude 2000\u20114500\u202fm, rated\u2011current derating and insulation\u2011gap correction are required, especially for closed\u2011box installation scenarios.<\/div>\n<\/div>\n<div style=\"border: 1px solid #ddd; margin-bottom: 8px;\">\n<div style=\"background: #f7f7f7; padding: 12px 16px; font-weight: bold;\">Q: Can multiple GFEVT1000\u201138R fuses run in parallel?<\/div>\n<div style=\"padding: 12px 16px;\">A: Yes, parallel mounting is allowed within dimensional guidelines to achieve higher total ampacity for large\u2011scale energy\u2011storage projects.<\/div>\n<\/div>\n<\/div>\n<p><!-- Product + FAQPage JSON\u2011LD \u8c37\u6b4c\u5bcc\u7ed3\u679c \/ AI\u2011Overview\u6293\u53d6\u6807\u8bb0 --><a href=\"https:\/\/essfuse.com\/wp-content\/uploads\/2026\/10\/GFEVT1000-38R-Series.-250-400A-1000Vdc-I.R-50kA-High-speed-fuse.pdf\">GFEVT1000-38R Series. 250-400A 1000Vdc I.R 50kA High-speed fuse<\/a><br \/>\n<script type=\"application\/ld+json\">\n[\n{\n\"@context\":\"https:\/\/schema.org\/\",\n\"@type\":\"Product\",\n\"name\":\"GFEVT1000\u201138R ev dc fuse\",\n\"sku\":\"GFEVT1000\u201138R Series\",\n\"mpn\":\"GFEVT1000\u201138R\",\n\"brand\":{\"@type\":\"Brand\",\"name\":\"ESSFUSE\"},\n\"manufacturer\":{\"@type\":\"Organization\",\"name\":\"Dongguan GongFu Electronics Co.,Ltd\"},\n\"description\":\"GFEVT1000\u201138R ev dc fuse,aR high\u2011speed 250\u2011400A 1000V DC,50kA breaking for energy storage & EV battery\u2011pack,IEC60269.4 UL248\u201113 JASO\u2011D622 RoHS CE compliant.\",\n\"offers\":{\"@type\":\"AggregateOffer\",\"availability\":\"https:\/\/schema.org\/InStock\",\"offerCount\":1},\n\"additionalProperty\":[\n{\"@type\":\"PropertyValue\",\"name\":\"Fuse Category\",\"value\":\"aR High\u2011speed DC protection fuse\"},\n{\"@type\":\"PropertyValue\",\"name\":\"Rated DC Voltage\",\"value\":\"1000V DC\"},\n{\"@type\":\"PropertyValue\",\"name\":\"Rated Current Range\",\"value\":\"250A\u2011400A\"},\n{\"@type\":\"PropertyValue\",\"name\":\"Breaking Capacity\",\"value\":\"50kA @1000V DC\"},\n{\"@type\":\"PropertyValue\",\"name\":\"Time Constant\",\"value\":\"\u22645ms\"},\n{\"@type\":\"PropertyValue\",\"name\":\"Mounting Spec\",\"value\":\"M8 bolt,12\u00b11.0N.m torque\"},\n{\"@type\":\"PropertyValue\",\"name\":\"Compliance & Certifications\",\"value\":\"IEC60269\u20114,UL248\u201113,JASO\u2011D622,CE,RoHS,REACH upon request\"},\n{\"@type\":\"PropertyValue\",\"name\":\"Anti\u2011Vibration\",\"value\":\"\u226520g high\u2011frequency vibration resistance\"},\n{\"@type\":\"PropertyValue\",\"name\":\"Altitude Notice\",\"value\":\"\u22642000m standard;2000\u20114500m needs current derating & insulation correction\"},\n{\"@type\":\"PropertyValue\",\"name\":\"Application\",\"value\":\"Energy\u2011storage system,EV\u2011HEV battery\u2011pack DC over\u2011current & short\u2011circuit protection\"}\n]\n},\n{\n\"@context\":\"https:\/\/schema.org\",\n\"@type\":\"FAQPage\",\n\"mainEntity\":[\n{\n\"@type\":\"Question\",\n\"name\":\"What fuse class is GFEVT1000\u201138R ev dc fuse?\",\n\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"GFEVT1000\u201138R belongs to aR high\u2011speed DC fuse, specially designed for energy\u2011storage and EV battery\u2011pack short\u2011circuit & over\u2011current protection.\"}\n},\n{\n\"@type\":\"Question\",\n\"name\":\"What is breaking\u2011capacity and time\u2011constant of GFEVT1000\u201138R?\",\n\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Rated interrupting capacity is 50kA at 1000V DC; time\u2011constant \u22645\u202fms for fast fault clearing for high\u2011power DC systems.\"}\n},\n{\n\"@type\":\"Question\",\n\"name\":\"What mounting requirement for GFEVT1000\u201138R?\",\n\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"M8 bolt\u2011on installation; recommended tightening torque 12\u00b11.0\u202fN.m to guarantee stable electrical contact.\"}\n},\n{\n\"@type\":\"Question\",\n\"name\":\"Does GFEVT1000\u201138R work at high altitude above 2000\u202fm?\",\n\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"For altitude 2000\u20114500\u202fm, rated\u2011current derating and insulation\u2011gap correction are required, especially for closed\u2011box installation scenarios.\"}\n},\n{\n\"@type\":\"Question\",\n\"name\":\"Can multiple GFEVT1000\u201138R fuses run in parallel?\",\n\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes, parallel mounting is allowed within dimensional guidelines to achieve higher total ampacity for large\u2011scale energy\u2011storage projects.\"}\n}\n]\n}\n]\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<pre><code>GFEVT1000\u201138R ev dc fuse is aR high\u2011speed DC fuse for energy storage and EV battery\u2011pack. Rated 250\u2011400A 1000V DC with 50kA interrupting capacity,IEC60269.4 UL248\u201113 JASO\u2011D622 RoHS CE compliant.\r\n<\/code><\/pre>","protected":false},"featured_media":16482,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[153],"product_tag":[],"class_list":["post-16477","product","type-product","status-publish","has-post-thumbnail","product_cat-british-standard-fuses","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/essfuse.com\/fr\/wp-json\/wp\/v2\/product\/16477","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/essfuse.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/essfuse.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/essfuse.com\/fr\/wp-json\/wp\/v2\/comments?post=16477"}],"version-history":[{"count":2,"href":"https:\/\/essfuse.com\/fr\/wp-json\/wp\/v2\/product\/16477\/revisions"}],"predecessor-version":[{"id":16481,"href":"https:\/\/essfuse.com\/fr\/wp-json\/wp\/v2\/product\/16477\/revisions\/16481"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/essfuse.com\/fr\/wp-json\/wp\/v2\/media\/16482"}],"wp:attachment":[{"href":"https:\/\/essfuse.com\/fr\/wp-json\/wp\/v2\/media?parent=16477"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/essfuse.com\/fr\/wp-json\/wp\/v2\/product_brand?post=16477"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/essfuse.com\/fr\/wp-json\/wp\/v2\/product_cat?post=16477"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/essfuse.com\/fr\/wp-json\/wp\/v2\/product_tag?post=16477"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}