{"id":4149,"date":"2025-10-21T17:04:00","date_gmt":"2025-10-21T17:04:00","guid":{"rendered":"https:\/\/1clickrepair.in\/ESS\/?post_type=product&#038;p=4149"},"modified":"2026-10-28T04:56:29","modified_gmt":"2026-10-28T04:56:29","slug":"fusible-ess-1500-v-cc-gfbfg4-d-105es-400-a-2000-a-pour-stockage-denergie","status":"publish","type":"product","link":"https:\/\/essfuse.com\/fr\/product\/1500v-dc-ess-fuse-gfbfg4-d-105es-400a-2000a-for-energy-storage\/","title":{"rendered":"Fusible de puissance CC 1500 V CC 400-2000 A, corps carr\u00e9, s\u00e9rie GFBFG4-D-105ES"},"content":{"rendered":"<div class=\"product-desc mb-4\">\n<div><strong>Dimensions (mm)<\/strong><\/div>\n<\/div>\n<p><img decoding=\"async\" src=\"https:\/\/v7-upload.digoodcms.com\/website_193\/2025-06-11\/20250329152614680.png?imageMogr2\/format\/webp\" alt=\"\" width=\"850\" \/><\/p>\n<h1>Fusible de puissance CC 1500 V CC 400-2000 A, corps carr\u00e9, s\u00e9rie GFBFG4-D-105ES<\/h1>\n<p>Le fusible CC haute vitesse GFBFG4-D-105ES, \u00e0 corps carr\u00e9, de classe aR, 1500 V CC, 400-2000 A, est un fusible \u00e0 boulonner de classe aR, de taille n\u00b0 4, con\u00e7u pour les syst\u00e8mes industriels de stockage d'\u00e9nergie et les \u00e9oliennes \u00e0 forte puissance. Tension nominale\u00a0: 1500 V CC. Pouvoir de coupure maximal\u00a0: 50\u00a0kA \u00e0 1500 V CC (L\/R \u2264 15\u00a0ms). Courant de coupure minimal\u00a0: &gt; 5\u00a0inA. Il offre une limitation de courant performante, une excellente tenue en cyclage, des bornes \u00e9tam\u00e9es de 3 \u00e0 5\u00a0\u00b5m et 4 trous de fixation M10. Ses performances sont conformes \u00e0 la norme UL-248-13. Conforme aux normes CE et RoHS. D\u00e9claration REACH disponible sur demande. Solution de protection fiable contre les courts-circuits pour les armoires de conversion d'\u00e9nergie \u00e9olienne et de syst\u00e8mes de stockage d'\u00e9nergie industriels de grande envergure.<\/p>\n<p><a href=\"https:\/\/essfuse.com\/wp-content\/uploads\/2025\/10\/GFBFG4-D-105ES-Series.-400-2000A-1500Vdc-IR-50kA-4-ESSEV-1.pdf\">S\u00e9rie GFBFG4-D-105ES.-400-2000A-1500Vdc-IR-50kA-4-ESSEV-1<\/a><\/p>\n<h2>Caract\u00e9ristiques principales<\/h2>\n<ul>\n<li>S\u00e9rie de mod\u00e8les\u00a0: GFBFG4\u2011D\u2011105ES Fusible d\u2019alimentation CC \u00e0 corps carr\u00e9 aR ESS<\/li>\n<li>Tension nominale\u00a0: 1\u00a0500\u00a0V CC<\/li>\n<li>Plage de courant\u00a0: 400\u00a0A \u00e0 2\u00a0000\u00a0A, Classe de fonctionnement\u00a0: aR (protection partielle contre les courts-circuits des semi-conducteurs)<\/li>\n<li>Capacit\u00e9 de coupure maximale\u00a0: 50\u00a0kA \u00e0 1\u00a0500\u00a0V CC (L\/R \u2264\u00a015\u00a0ms)<\/li>\n<li>Courant de coupure minimal : &gt; 5 pouces<\/li>\n<li>Forte capacit\u00e9 de limitation de courant pour les conditions de courant de d\u00e9faut \u00e9lev\u00e9es<\/li>\n<li>Capacit\u00e9 de cyclage sup\u00e9rieure pour les fluctuations fr\u00e9quentes des conditions de fonctionnement dans les syst\u00e8mes de stockage d'\u00e9nergie et les centrales \u00e9oliennes.<\/li>\n<li>Bo\u00eetier carr\u00e9 n\u00b0 4, 4 trous de fixation pour boulons M10, bornes \u00e9tam\u00e9es 3-5 \u00b5m<\/li>\n<li>Haute stabilit\u00e9 m\u00e9canique pour l'installation d'armoires industrielles robustes<\/li>\n<li>Conforme aux normes : UL-248-13, CE, RoHS ; conformit\u00e9 REACH disponible sur demande<\/li>\n<\/ul>\n<h2>Sp\u00e9cifications techniques g\u00e9n\u00e9rales<\/h2>\n<table style=\"border: 1px solid #333; border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px; width: 42%;\">Gamme de produits<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">Fusible d'alimentation CC ESS \u00e0 corps carr\u00e9 s\u00e9rie GFBFG4-D-105ES<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Tension nominale<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">1500 V CC<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Plage de courant nominal<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">400A\u20112000A (classe de fonctionnement aR)<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Capacit\u00e9 de rupture maximale<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">50 kA \u00e0 1500 V CC (L\/R \u2264 15 ms)<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Courant de coupure minimal<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">&gt;5 pouces<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Construction corporelle<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">n\u00b0 4, corps carr\u00e9, 4 trous de fixation M10, \u00e9tam\u00e9 3-5 \u03bcm<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Normes et homologations<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">Conforme aux normes UL-248-13, CE et RoHS<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Temp\u00e9rature de fonctionnement<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">\u20115\u2103 ~ +40\u2103 (normal) ; \u201140\u2103 ~ +85\u2103 (admissible)<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Temp\u00e9rature de stockage<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">\u201140\u2103 ~ +120\u2103<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Liste des r\u00e9f\u00e9rences et param\u00e8tres \u00e9lectriques (Test \u00e0 1500 VCC, 50 kA, L\/R \u2264 15 ms)<\/h2>\n<table style=\"border: 1px solid #333; border-collapse: collapse; width: 100%; font\u2011size: 11px;\">\n<tbody>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">Num\u00e9ro de pi\u00e8ce<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">Courant nominal<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">Pr\u00e9-arc I\u00b2t (A\u00b2s)<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">D\u00e9gagement I\u00b2t (A\u00b2s)<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">Perte de puissance (W) \u00e0 1,0 pouce<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFBFG4\u2011400D\u2011105ES<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">400A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">42250<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">255800<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">168<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFBFG4\u2011500D\u2011105ES<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">500A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">93500<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">585500<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">175<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFBFG4\u2011630D\u2011105ES<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">630A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">163000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">1020500<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">185<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFBFG4\u2011700D\u2011105ES<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">700A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">225500<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">1320000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">192<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFBFG4\u2011800D\u2011105ES<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">800A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">310000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">1970000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">196<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFBFG4\u2011900D\u2011105ES<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">900A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">425000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">2600000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">200<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFBFG4\u20111000D\u2011105ES<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">1000A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">640000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">4005000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">210<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFBFG4\u20111100D\u2011105ES<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">1100A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">780300<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">4950000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">220<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFBFG4\u20111200D\u2011105ES<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">1200A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">915000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">5865500<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">242<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFBFG4\u20111250D\u2011105ES<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">1250A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">1080000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">7150600<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">255<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFBFG4\u20111300D\u2011105ES<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">1300A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">1300000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">8040000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">260<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFBFG4\u20111350D\u2011105ES<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">1350A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">1320000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">9060000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">266<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFBFG4\u20111400D\u2011105ES<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">1400A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">1665000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">10700000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">275<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFBFG4\u20111500D\u2011105ES<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">1500A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">1870000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">11950500<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">282<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFBFG4\u20111600D\u2011105ES<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">1600A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">2235000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">14880000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">294<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFBFG4\u20111800D\u2011105ES<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">1800A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">2850000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">17950000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">313<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">*GFBFG4\u20112000D\u2011105ES<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">2000A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">3750000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">23900000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">345<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Sc\u00e9narios d&#039;application<\/h2>\n<p>Le fusible de puissance CC GFBFG4-D-105ES \u00e0 corps carr\u00e9, de classe aR et de 400 \u00e0 2000 A, est con\u00e7u pour les projets industriels CC \u00e0 forte intensit\u00e9 de courant dans le secteur des \u00e9nergies nouvelles. Il est principalement utilis\u00e9 dans les syst\u00e8mes de stockage d'\u00e9nergie industriels de grande envergure et les armoires de convertisseurs d'\u00e9nergie \u00e9olienne. Sa caract\u00e9ristique de protection partielle de classe aR assure une protection fiable contre les courts-circuits pour les semi-conducteurs de puissance et les \u00e9quipements CC haute puissance, m\u00eame en cas de courants de d\u00e9faut importants.<\/p>\n<h2>Notes d&#039;installation et d&#039;utilisation<\/h2>\n<ul>\n<li>#4 corps carr\u00e9 avec quatre trous de montage M10 ; appliquer la valeur de couple de boulon correcte pour \u00e9viter un mauvais contact et un risque de surchauffe ; traitement de surface des bornes \u00e9tam\u00e9 3-5 \u03bcm.<\/li>\n<li>Courant de fonctionnement continu recommand\u00e9 \u226475% du courant nominal du fusible ; appliquer un facteur de r\u00e9duction de temp\u00e9rature Kt pour une temp\u00e9rature ambiante sup\u00e9rieure \u00e0 40\u2111.<\/li>\n<li>Altitude \u2264 2\u00a0000\u00a0m\u00a0: aucune r\u00e9duction de puissance\u00a0; installation en caisson ferm\u00e9 de 2\u00a0000 \u00e0 4\u00a0500\u00a0m\u00a0: r\u00e9duction de 2\u00a0% \u00e0 5\u00a0% du courant nominal par tranche de 1\u00a0000\u00a0m d\u2019altitude. L\u2019influence de l\u2019altitude est g\u00e9n\u00e9ralement n\u00e9gligeable pour une installation en ext\u00e9rieur. \u00c0 haute altitude, v\u00e9rifier l\u2019isolation conform\u00e9ment \u00e0 la norme GB\/T\u00a016935.1.<\/li>\n<li>Permet un montage vertical, horizontal et inclin\u00e9 ; \u00e9vite les impacts n\u00e9gatifs de la gravit\u00e9 et des vibrations gr\u00e2ce \u00e0 une construction \u00e0 contact ressort.<\/li>\n<li>Le refroidissement par air forc\u00e9 peut am\u00e9liorer la dissipation de chaleur et augmenter le courant de fonctionnement admissible, voir le coefficient de correction Kv.<\/li>\n<li>Ne remplacez PAS le fusible sous charge CC sous tension, sauf si l&#039;appareillage est \u00e9quip\u00e9 d&#039;un sectionneur certifi\u00e9.<\/li>\n<li>Remplacez imm\u00e9diatement le fusible en cas de dommage m\u00e9canique, de fissure ou de d\u00e9formation de son corps.<\/li>\n<li>Des tests de validation de fiabilit\u00e9 suppl\u00e9mentaires seront effectu\u00e9s pour les environnements de travail industriels soumis \u00e0 des vibrations extr\u00eamement \u00e9lev\u00e9es.<\/li>\n<li>S\u00e9lectionnez une section transversale de conducteur en cuivre adapt\u00e9e pour les bornes afin de contr\u00f4ler les performances d&#039;\u00e9l\u00e9vation de temp\u00e9rature.<\/li>\n<li>*Remarque\u00a0: Mod\u00e8le marqu\u00e9 d\u2019un ast\u00e9risque, veuillez confirmer aupr\u00e8s du fabricant avant de commander.<\/li>\n<\/ul>\n<h2>Exigences en mati\u00e8re d&#039;emballage et de stockage<\/h2>\n<p>Conditionnement en vrac dans son emballage d'origine standard. Stockage dans un entrep\u00f4t propre et exempt de poussi\u00e8re. Temp\u00e9rature de stockage\u00a0: -40\u00a0\u00b0C \u00e0 +120\u00a0\u00b0C\u00a0; humidit\u00e9 relative\u00a0: \u2264\u00a070\u00a0% \u00e0 40\u00a0\u00b0C, \u2264\u00a080\u00a0% \u00e0 30\u00a0\u00b0C, \u2264\u00a090\u00a0% \u00e0 20\u00a0\u00b0C. Nous proposons des tests d'\u00e9chantillons, la personnalisation OEM et un approvisionnement r\u00e9gulier en gros volumes pour les fabricants de syst\u00e8mes de stockage d'\u00e9nergie industrielle et d'\u00e9oliennes. D\u00e9claration REACH disponible sur demande.<\/p>\n<h2>FAQ<\/h2>\n<p><strong>Q : Quelle est la valeur nominale du fusible d'alimentation CC \u00e0 corps carr\u00e9 GFBFG4\u2011D\u2011105ES s\u00e9rie 1500VDC 400\u20112000A ?<\/strong><br \/>\nA : Valeur nominale 1500 VCC, plage de courant 400\u20112000 A, classe de protection \u00e0 plage partielle aR, capacit\u00e9 de coupure maximale 50 kA \u00e0 1500 VCC (L\/R \u2264 15 ms), courant de coupure minimal &gt; 5 In.<\/p>\n<p><strong>Q : Qu\u2019est-ce qu\u2019un fusible \u00e0 plage partielle de classe R ?<\/strong><br \/>\nA : Le fusible \u00e0 plage partielle de classe R est con\u00e7u pour la protection contre les d\u00e9fauts de court-circuit importants des dispositifs semi-conducteurs de puissance, agissant principalement dans des conditions de courant de d\u00e9faut \u00e9lev\u00e9.<\/p>\n<p><strong>Q : Quelle structure de montage pour GFBFG4\u2011D\u2011105ES ?<\/strong><br \/>\nA : Bo\u00eetier carr\u00e9 n\u00b0 4 avec quatre trous de fixation pour boulons M10, bornes \u00e9tam\u00e9es de 3 \u00e0 5 \u03bcm.<\/p>\n<p><strong>Q : \u00c0 quelles normes le GFBFG4\u2011D\u2011105ES est-il conforme ?<\/strong><br \/>\nA: Performances r\u00e9f\u00e9renc\u00e9es \u00e0 UL\u2011248\u201113, conformes CE et RoHS ; document REACH disponible sur demande.<\/p>\n<p><strong>Q : Principaux sc\u00e9narios d'application pour GFBFG4\u2011D\u2011105ES ?<\/strong><br \/>\nA : Protection contre les courts-circuits des syst\u00e8mes de stockage d'\u00e9nergie industriels \u00e0 grande \u00e9chelle et des armoires de conversion d'\u00e9nergie \u00e9olienne.<\/p>","protected":false},"excerpt":{"rendered":"<pre><code>Fusible CC GFBFG4\u2011D\u2011105ES \u00e0 corps carr\u00e9 aR ESS, 1500 VCC 400\u20112000 A, capacit\u00e9 de coupure de 50 kA pour le stockage d'\u00e9nergie industriel haute puissance et la protection contre les courts-circuits des \u00e9oliennes.\r\n<\/code><\/pre>","protected":false},"featured_media":16041,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[144],"product_tag":[],"class_list":["post-4149","product","type-product","status-publish","has-post-thumbnail","product_cat-energy-storage-fuses-ess","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/essfuse.com\/fr\/wp-json\/wp\/v2\/product\/4149","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/essfuse.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/essfuse.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/essfuse.com\/fr\/wp-json\/wp\/v2\/comments?post=4149"}],"version-history":[{"count":3,"href":"https:\/\/essfuse.com\/fr\/wp-json\/wp\/v2\/product\/4149\/revisions"}],"predecessor-version":[{"id":16039,"href":"https:\/\/essfuse.com\/fr\/wp-json\/wp\/v2\/product\/4149\/revisions\/16039"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/essfuse.com\/fr\/wp-json\/wp\/v2\/media\/16041"}],"wp:attachment":[{"href":"https:\/\/essfuse.com\/fr\/wp-json\/wp\/v2\/media?parent=4149"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/essfuse.com\/fr\/wp-json\/wp\/v2\/product_brand?post=4149"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/essfuse.com\/fr\/wp-json\/wp\/v2\/product_cat?post=4149"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/essfuse.com\/fr\/wp-json\/wp\/v2\/product_tag?post=4149"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}