High‑Speed Fuse GFEVT1500‑D‑105ES 400‑2000A 1500VDC Square Fuse
GFEVT1500‑D‑105ES square high‑speed 1500Vdc aR fuse,400‑2000A fast‑acting DC fuse,50kA interrupt rating,UL248‑13 & IEC60269‑4 certified for energy‑storage,wind‑power and battery pack short‑circuit protection.
Need a Fuse for Your Project?
Share your requirements with us for product guidance and a quotation.
GFEVT1500‑D‑105ES High‑Speed Fuse 400‑2000A 1500VDC High‑Voltage DC Fuse
Our High‑Speed Fuse model GFEVT1500‑D‑105ES is square‑body fast‑acting aR‑class DC fuse for 1500Vdc new‑energy systems, rated current from 400A‑2000A. It features 50kA high interrupting capacity, low arc‑voltage & low energy let‑through I²t, UL248‑13 & IEC60269‑4 compliant. Widely deployed for energy‑storage containers,battery packs,wind‑power equipment and DC‑drive short‑circuit & over‑current protection.
Main Electrical Ratings & Key Specifications
| Item | Parameter |
|---|---|
| Rated Voltage | 1500 Vdc |
| Rated Current Range | 400A ~ 2000A , Size 4# |
| Interrupting Capacity | 50kA@1500Vdc (L/R ≤15ms) |
| Fuse Class | aR (partial‑range semiconductor protection) |
| Minimum Breaking Current | >3 In |
| Characteristic | Fast‑Acting High‑Speed DC Fuse, low I²t let‑through |
| Certifications & Standards | UL248‑13, IEC 60269‑4, RoHS Compliant; REACH statement upon request |
| Operating Temperature | ‑40℃ ~ +85℃; Standard working:‑5℃ ~ +40℃ |
| Mounting | 4pcs M10 bolts; Hole max depth 12.5mm, min thread‑length:10mm; Tin‑plated 3‑5μm |
| Typical Application | Energy‑storage ESS, battery‑pack, wind‑power, DC‑drive system short‑circuit protection |
Complete Model List | Melting / Clearing I²t & Power‑Loss Data
| Part Number | Rated Amps | Size | Melting A²s @50kA | Clearing A²s @50kA | Power Loss(W) |
|---|---|---|---|---|---|
| GFEVT1500‑400D‑105ES | 400A | 4# | 25,840 | 136,400 | 198 |
| GFEVT1500‑500D‑105ES | 500A | 4# | 57,350 | 275,430 | 200 |
| GFEVT1500‑630D‑105ES | 630A | 4# | 117,640 | 563,500 | 232 |
| GFEVT1500‑700D‑105ES | 700A | 4# | 164,320 | 783,000 | 249 |
| GFEVT1500‑800D‑105ES | 800A | 4# | 242,100 | 1,160,250 | 256 |
| GFEVT1500‑900D‑105ES | 900A | 4# | 345,700 | 1,668,800 | 277 |
| GFEVT1500‑1000D‑105ES | 1000A | 4# | 470,500 | 2,290,100 | 293 |
| GFEVT1500‑1100D‑105ES | 1100A | 4# | 625,200 | 3,005,000 | 312 |
| GFEVT1500‑1200D‑105ES | 1200A | 4# | 752,500 | 3,600,200 | 320 |
| GFEVT1500‑1250D‑105ES | 1250A | 4# | 915,200 | 4,430,000 | 325 |
| GFEVT1500‑1300D‑105ES | 1300A | 4# | 1,005,500 | 5,230,500 | 338 |
| GFEVT1500‑1350D‑105ES | 1350A | 4# | 1,290,000 | 6,245,000 | 348 |
| GFEVT1500‑1400D‑105ES | 1400A | 4# | 1,350,900 | 6,980,500 | 354 |
| GFEVT1500‑1500D‑105ES | 1500A | 4# | 1,580,560 | 7,630,000 | 362 |
| GFEVT1500‑1600D‑105ES | 1600A | 4# | 1,940,500 | 9,295,950 | 375 |
| GFEVT1500‑1800D‑105ES | 1800A | 4# | 2,728,600 | 13,120,650 | 394 |
| GFEVT1500‑2000D‑105ES | 2000A | 4# | 3,300,980 | 18,560,370 | 412 |
Mechanical Dimension
Square‑body construction, overall dimension 154±3 mm × 105±1.5 mm. 4‑pcs M10 mounting holes on each side; max hole‑depth:12.5 mm, minimum thread‑length 10 mm. Terminals tin‑plated 3‑5 microns. Please check dimension drawing for full mechanical specifications.
Derating & Installation Instructions
- Recommended continuous operating current ≤ 75% of fuse rated‑current under standard‑5℃~40℃ ambient environment.
- For ambient temperature above 40℃, apply temperature‑derating factor Kt. For closed‑cabinet installation at altitude 2000‑4500 m, apply altitude‑derating Ka: derate 2‑5% per 1000‑meter elevation; open‑air deployment normally ignores altitude‑derating.
- Support vertical, horizontal and inclined mounting. Avoid gravity and vibration side‑effects for spring‑contact structures.
- Terminal contact resistance shall be kept low to prevent extra over‑heating and power‑loss rise.
Typical Applications
- Energy‑storage ESS container & DC main‑circuit protection
- Large‑capacity lithium‑ion battery‑pack short‑circuit protection
- Wind‑power converter DC‑side protection
- DC drives and new‑energy power‑equipment over‑current & short‑circuit protection
Download Datasheet
GFHVT1500-D-105ES-Series.-400-2000A-1500Vdc-IR-50kA-4-Fast-Acting-Fuse
Frequently Asked Questions
- What is rated voltage of GFEVT1500‑D‑105ES series?
- This high‑speed fuse is rated for 1500Vdc, designed for DC‑only new‑energy circuits, not intended for AC‑system usage.
- What current ratings are available?
- 400A,500A,630A,700A,800A,900A,1000A,1100A,1200A,1250A,1300A,1350A,1400A,1500A,1600A,1800A,2000A (Size 4#).
- What is its interrupting capacity and fuse class?
- Interrupting capacity:50kA@1500Vdc(L/R ≤15ms); fuse class aR; minimum breaking current>3 In.
- What standards and certifications apply?
- Designed per UL248‑13 & IEC 60269‑4; RoHS‑compliant; REACH declaration can be supplied upon request.
- What is the rule for continuous‑current selection?
- Keep continuous working current ≤ 75% of fuse rated‑ampere under‑5℃~40℃ standard ambient.
- Must I derate for high‑temperature or high‑altitude?
- Yes. Above 40℃ apply temperature‑derating Kt. For closed‑box installation 2000‑4500 m altitude derate 2‑5% /1000 m; open‑air application generally skips altitude‑derating.
- Can I install this fuse horizontally or inclined?
- Vertical, horizontal and inclined mounting are allowed. Prevent gravity and vibration from degrading spring‑contact electrical connections.
- What are main target‑applications?
- ESS energy‑storage systems,battery‑pack protection,wind‑power converters,DC‑drives and other 1500Vdc new‑energy power‑equipment short‑circuit protection.
- Can I replace the fuse under live‑load?
- Do NOT replace fuse while carrying live‑load unless a matched fuse‑disconnector switch assembly is implemented.
- What are the storage conditions?
- Store in original package:‑40℃~+85℃, RH ≤70% at 40℃, dust‑free warehouse environment.