{"id":4176,"date":"2025-10-21T17:04:10","date_gmt":"2025-10-21T17:04:10","guid":{"rendered":"https:\/\/1clickrepair.in\/ESS\/?post_type=product&#038;p=4176"},"modified":"2026-10-27T01:59:02","modified_gmt":"2026-10-27T01:59:02","slug":"ceramic-car-fuse-anl-b30bsf51-mega-bolt-down-fuses-for-automotive-circuits","status":"publish","type":"product","link":"https:\/\/essfuse.com\/hi\/product\/ceramic-car-fuse-anl-b30bsf51-mega-bolt-down-fuses-for-automotive-circuits\/","title":{"rendered":"Ceramic Car Fuse, ANL Mega Bolt Down Fuses for Automotive DC Circuits"},"content":{"rendered":"<p>Dimensions (mm)<br \/>\n<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/v7-upload.digoodcms.com\/website_193\/2025-07-16\/3b1.png?imageMogr2\/format\/webp\" alt=\"Dimensions\" width=\"850\" height=\"503\" \/><\/p>\n<div>\n<p>Ceramic high\u2011temp fork bolt\u2011down short\u2011circuit protector is a heavy\u2011duty DC protective device compliant with ISO 20934 Special Purpose Fuses. Equipped with high\u2011temperature\u2011resistant ceramic shell and tin\u2011plated copper\u2011alloy terminals, this protector adopts dual M8 bolt installation with 51\u202fmm hole centre\u2011to\u2011centre spacing. <strong>Important note: This is a short\u2011circuit\u2011only protector and cannot provide overload\u2011protection.<\/strong> It is designed for 70V DC heavy\u2011current circuits in new\u2011energy vehicles, marine equipment and energy\u2011storage battery systems.<\/p>\n<h2>Core Features<\/h2>\n<ul>\n<li>High\u2011temperature resistant ceramic shell, stable performance under harsh on\u2011board thermal conditions<\/li>\n<li>Tin\u2011plated copper\u2011alloy terminals; dual M8 bolt holes with 51\u202f\u202fmm centre\u2011to\u2011centre distance<\/li>\n<li>Specified mounting torque: <strong>12.0\u202fNm \u00b11\u202fNm<\/strong> to ensure reliable heavy\u2011current contact performance<\/li>\n<li>Rated breaking capacity: 70V DC; short\u2011circuit\u2011only device, no overload\u2011protection capability<\/li>\n<li>Compliant with ISO 20934 Special Purpose Fuses industry standard<\/li>\n<li>Wide operating temperature:\u201140\u2103 ~ +125\u2103; maximum allowable contact\u2011point temperature up to 150\u2103<\/li>\n<li>Broad current range 40A\u2011650A for heavy\u2011duty battery main\u2011circuit short\u2011circuit protection<\/li>\n<\/ul>\n<h2>General Specifications<\/h2>\n<table style=\"border: 1px solid #000; border-collapse: collapse; width: 100%;\">\n<thead>\n<tr>\n<th style=\"border: 1px solid #000; padding: 9px;\">Item<\/th>\n<th style=\"border: 1px solid #000; padding: 9px;\">Parameter<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Shell Material<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">Ceramic high temperature resistant<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Terminal<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">Copper alloy, tin\u2011plated, 2 x M8 bolts, 51\u202fmm hole centre distance<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Mounting Torque<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">12.0\u202fNm \u00b11\u202fNm<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Breaking Capacity<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">70V DC<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Compliance Standard<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">ISO 20934 Special Purpose Fuses<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Operating Temperature Range<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u201140\u2103 ~ +125\u2103; Max contact\u2011point temperature:150\u2103<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Device Type<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">Short\u2011circuit protector only (without overload\u2011protection)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Time\u2011Current Characteristics<\/h2>\n<table style=\"border: 1px solid #000; border-collapse: collapse; width: 100%;\">\n<thead>\n<tr>\n<th style=\"border: 1px solid #000; padding: 9px;\">% of Rated Current<\/th>\n<th style=\"border: 1px solid #000; padding: 9px;\">80A\u2011250A Min \/ Max(s)<\/th>\n<th style=\"border: 1px solid #000; padding: 9px;\">300A\u2011650A Min \/ Max(s)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">75%<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u2011 \/ \u2011<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u2011 \/ 14400 s<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">100%<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">14400 s \/ \u2011<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u2011 \/ \u2011<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">135%<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">120 s \/ 1800 s<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u2011 \/ \u2011<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">200%<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">1 s \/ 15 s<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">1 s \/ 15 s<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">350%<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">0.300 s \/ 5 s<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">0.500 s \/ 5 s<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">600%<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">0.100 s \/ 1 s<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">0.100 s \/ 1 s<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Electrical Ratings &amp; Typical Voltage Drop<\/h2>\n<table style=\"border: 1px solid #000; border-collapse: collapse; width: 100%;\">\n<thead>\n<tr>\n<th style=\"border: 1px solid #000; padding: 9px;\">Internal Model No.<\/th>\n<th style=\"border: 1px solid #000; padding: 9px;\">Rated Current(A)<\/th>\n<th style=\"border: 1px solid #000; padding: 9px;\">Typ Voltage Drop<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">ANL\u2011B30B040<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">40A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u2264110 mV<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">ANL\u2011B30B050<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">50A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u2264110 mV<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">ANL\u2011B30B060<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">60A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u2264110 mV<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">ANL\u2011B30B070<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">70A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u2264110 mV<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">ANL\u2011B30B080<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">80A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u2264110 mV<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">ANL\u2011B30B100<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">100A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u2264110 mV<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">ANL\u2011B30B125<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">125A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u2264110 mV<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">ANL\u2011B30B150<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">150A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u2264110 mV<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">ANL\u2011B30B175<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">175A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u2264110 mV<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">ANL\u2011B30B200<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">200A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u2264110 mV<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">ANL\u2011B30B225<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">225A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u2264110 mV<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">ANL\u2011B30B250<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">250A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u2264110 mV<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">ANL\u2011B30B275<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">275A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u226480 mV<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">ANL\u2011B30B300<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">300A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u226480 mV<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">ANL\u2011B30B350<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">350A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u226480 mV<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">ANL\u2011B30B400<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">400A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u226480 mV<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">ANL\u2011B30B450<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">450A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u226480 mV<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">ANL\u2011B30B500<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">500A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u226480 mV<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">ANL\u2011B30B550<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">550A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u226480 mV<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">ANL\u2011B30B600<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">600A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u226480 mV<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">ANL\u2011B30B650<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">650A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u226480 mV<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Typical Application Scenarios<\/h2>\n<ul>\n<li>70V DC new\u2011energy vehicle battery bank short\u2011circuit protection<\/li>\n<li>Heavy\u2011duty special vehicle and mobile equipment DC power distribution<\/li>\n<li>RV, yacht and marine vessel high\u2011current DC\u2011system protection<\/li>\n<li>Energy\u2011storage system main\u2011circuit short\u2011circuit protection<\/li>\n<\/ul>\n<p>Match this ceramic high\u2011temp fork bolt\u2011down short\u2011circuit protector with our <a href=\"https:\/\/essfuse.com\/product-category\/fuse-holders\/bolt-fuse-holder\/\">bolt\u2011down fuse holders<\/a> for complete power\u2011distribution assembly.<\/p>\n<h2>Installation &amp; Safety Notes<\/h2>\n<ul>\n<li><strong>This is short\u2011circuit\u2011only protector and cannot provide overload\u2011protection function.<\/strong><\/li>\n<li>Disconnect main power before installation or replacement to avoid accidental short\u2011circuit risk.<\/li>\n<li>Observe mounting torque 12.0\u202fNm \u00b11\u202fNm; loose contact will cause over\u2011heating under heavy\u2011current load.<\/li>\n<li>For enclosed high\u2011temperature compartments, temperature derating assessment shall be performed.<\/li>\n<li>Only replace with same\u2011specification protector to keep original circuit\u2011protection performance.<\/li>\n<\/ul>\n<h2>FAQ<\/h2>\n<p><strong>Q: What is ceramic high\u2011temp fork bolt\u2011down short\u2011circuit protector?<\/strong><br \/>\nA: Ceramic high\u2011temp fork bolt\u2011down short\u2011circuit protector is ISO20934\u2011compliant fork\u2011bolt DC protective component with ceramic high\u2011temperature shell. It serves for 70V DC heavy\u2011current short\u2011circuit protection in EV, marine and energy\u2011\u2011storage systems.<\/p>\n<p><strong>Q: Can this protector defend against overload faults?<\/strong><br \/>\nA: No. It is short\u2011circuit\u2011only protector and offers no overload\u2011protection capability.<\/p>\n<p><strong>Q: What mounting specification should I follow?<\/strong><br \/>\nA: Dual M8 bolt holes with 51\u202fmm centre\u2011distance; recommended tightening torque:12.0\u202fNm \u00b11\u202fNm.<\/p>\n<p><strong>Q: Which standard does this product comply with?<\/strong><br \/>\nA: Complies with ISO 20934 Special Purpose Fuses standard.<\/p>\n<p><strong>Q: What ampere ratings are available?<\/strong><br \/>\nA: Available ratings:40A,50A,60A,70A,80A,100A,125A,150A,175A,200A,225A,250A,275A,300A,350A,400A,450A,500A,550A,600A,650A.<\/p>\n<p><strong>Q: What is its breaking\u2011capacity?<\/strong><br \/>\nA: Rated breaking\u2011capacity is 70V DC.<\/p>\n<h2>Get Quotation &amp; Technical Support<\/h2>\n<p>Please tell us required current rating, quantity and application scenario. Our engineering team can provide datasheet, bulk\u2011price and professional selection guidance for your DC\u2011project.<\/p>\n<\/div>\n<p><script type=\"application\/ld+json\">\n{\n\"@context\":\"https:\/\/schema.org\",\n\"@type\":\"FAQPage\",\n\"mainEntity\":[\n{\"@type\":\"Question\",\"name\":\"What is ceramic high\u2011temp fork bolt\u2011down short\u2011circuit protector?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Ceramic high\u2011temp fork bolt\u2011down short\u2011circuit protector is ISO20934\u2011compliant fork\u2011bolt DC protective component with ceramic high\u2011temperature shell. It serves for 70V DC heavy\u2011current short\u2011circuit protection in EV, marine and energy\u2011storage systems.\"}},\n{\"@type\":\"Question\",\"name\":\"Can this protector defend against overload faults?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. It is short\u2011circuit\u2011only protector and offers no overload\u2011protection capability.\"}},\n{\"@type\":\"Question\",\"name\":\"What mounting specification should I follow?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Dual M8 bolt holes with 51\u202fmm centre\u2011distance; recommended tightening torque:12.0\u202fNm \u00b11\u202fNm.\"}},\n{\"@type\":\"Question\",\"name\":\"Which standard does this product comply with?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Complies with ISO 20934 Special Purpose Fuses standard.\"}},\n{\"@type\":\"Question\",\"name\":\"What ampere ratings are available?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Available ratings:40A,50A,60A,70A,80A,100A,125A,150A,175A,200A,225A,250A,275A,300A,350A,400A,450A,500A,550A,600A,650A.\"}},\n{\"@type\":\"Question\",\"name\":\"What is its breaking\u2011capacity?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Rated breaking\u2011capacity is 70V DC.\"}}\n]\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<pre><code>Ceramic high\u2011temp fork bolt\u2011down short\u2011circuit protector, ISO20934 40A\u2011650A 70V DC, M8 51\u202fmm mounting, short\u2011circuit\u2011only protective device.\r\n<\/code><\/pre>","protected":false},"featured_media":13992,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[145,149],"product_tag":[],"class_list":["post-4176","product","type-product","status-publish","has-post-thumbnail","product_cat-automobile-fuse","product_cat-bolt-down-fuses","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/essfuse.com\/hi\/wp-json\/wp\/v2\/product\/4176","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/essfuse.com\/hi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/essfuse.com\/hi\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/essfuse.com\/hi\/wp-json\/wp\/v2\/comments?post=4176"}],"version-history":[{"count":3,"href":"https:\/\/essfuse.com\/hi\/wp-json\/wp\/v2\/product\/4176\/revisions"}],"predecessor-version":[{"id":15549,"href":"https:\/\/essfuse.com\/hi\/wp-json\/wp\/v2\/product\/4176\/revisions\/15549"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/essfuse.com\/hi\/wp-json\/wp\/v2\/media\/13992"}],"wp:attachment":[{"href":"https:\/\/essfuse.com\/hi\/wp-json\/wp\/v2\/media?parent=4176"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/essfuse.com\/hi\/wp-json\/wp\/v2\/product_brand?post=4176"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/essfuse.com\/hi\/wp-json\/wp\/v2\/product_cat?post=4176"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/essfuse.com\/hi\/wp-json\/wp\/v2\/product_tag?post=4176"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}