{"id":4103,"date":"2025-10-21T17:03:50","date_gmt":"2025-10-21T17:03:50","guid":{"rendered":"https:\/\/1clickrepair.in\/ESS\/?post_type=product&#038;p=4103"},"modified":"2026-10-28T03:55:32","modified_gmt":"2026-10-28T03:55:32","slug":"gfevf-150-70a-1000a-125v-150v-high-speed-semiconductor-fuse","status":"publish","type":"product","link":"https:\/\/essfuse.com\/it\/prodotto\/gfevf-150-70a-1000a-125v-150v-high-speed-semiconductor-fuse\/","title":{"rendered":"GFEVF150\u2011Series aR Semiconductor DC Power Fuse 125\u2011150VDC 70\u20111000A"},"content":{"rendered":"<h1>GFEVF150\u2011Series aR Semiconductor DC Power Fuse 125\u2011150VDC 70\u20111000A<\/h1>\n<p>GFEVF150\u2011Series aR Semiconductor DC Power Fuse 125\u2011150VDC 70\u20111000A is north\u2011american standard high\u2011speed aR\u2011class semiconductor DC power fuse, rated for 125\u2011150VDC with max 50kA@150VDC breaking capacity, time constant 2.5\u00b10.5\u202fms. Features low arc\u2011voltage, low I\u00b2t let\u2011through energy, low watt losses, superior cycling capability, excellent mechanical shock and vibration resistance. Supports parallel installation for higher ampacity within dimensional guidelines. Complies with UL\u2011248\u201113, IEC\u202f60269\u20114, CE and RoHS. Widely used for energy\u2011storage battery\u2011pack, DC drives, power converters, rectifier equipment and DC relay backup semiconductor short\u2011circuit protection.<\/p>\n<p><a href=\"https:\/\/essfuse.com\/wp-content\/uploads\/2025\/10\/GFEVF150V-Semiconductor-fuse.pdf\">GFEVF150V-Semiconductor-fuse<\/a><\/p>\n<h2>Key Features<\/h2>\n<ul>\n<li>Model Series: GFEVF150 North\u2011American Style aR Semiconductor DC Power Fuse<\/li>\n<li>Rated Voltage: 125\u2011150\u202fVDC<\/li>\n<li>Current Range: 70A\u20111000A, Operation Class: aR (semiconductor short\u2011circuit protection)<\/li>\n<li>Max Breaking Capacity: 50kA @150VDC<\/li>\n<li>Time Constant: 2.5\u00b10.5\u202fms<\/li>\n<li>Low arc\u2011voltage, low energy let\u2011through I\u00b2t characteristics<\/li>\n<li>Low watt losses, superior cycling capability<\/li>\n<li>Two body size options:70\u2011400A \/ 500\u20111000A bolt\u2011on type<\/li>\n<li>Parallel mounting permitted for higher ampacity within dimensional guidelines<\/li>\n<li>Excellent mechanical shock &amp; vibration resistance<\/li>\n<li>Compliant: UL\u2011248\u201113, IEC\u202f60269\u20114, CE, RoHS; REACH available upon request<\/li>\n<\/ul>\n<h2>General Technical Specifications<\/h2>\n<table style=\"border: 1px solid #333; border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px; width: 42%;\">Product Series<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">GFEVF150\u2011Series North\u2011American Style aR Semiconductor DC Power Fuse<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Rated Voltage<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">125\u2011150\u202fV DC<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Rated Current Range<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">70A\u20111000A (aR operation class)<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Max Breaking Capacity<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">50kA @150VDC<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Time Constant<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">2.5\u00b10.5\u202fms<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Body Sizes<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">70\u2011400A, 500\u20111000A bolt\u2011on body versions<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Standards Compliance<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">UL\u2011248\u201113, IEC\u202f60269\u20114, CE, RoHS<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Operating Temperature<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">\u20115\u2103 ~ +40\u2103(regular);\u201140\u2103~+85\u2103(allowable)<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Storage Temperature<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">\u201140\u2103 ~ +120\u2103<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Part Number List &amp; Electrical Parameters<\/h2>\n<table style=\"border: 1px solid #333; border-collapse: collapse; width: 100%; font\u2011size: 11px;\">\n<tbody>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">Part Number<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">Rated Current<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">Pre\u2011arc A\u00b2S<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">Clearing A\u00b2S @150V<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">Power Loss(W)<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFEVF150\u201170A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">70A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">470<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">4000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">6.9<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFEVF150\u201180A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">80A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">670<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">6000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">7.7<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFEVF150\u2011100A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">100A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">1200<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">12000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">9.0<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFEVF150\u2011125A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">125A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">1870<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">18000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">11.2<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFEVF150\u2011150A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">150A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">2700<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">26000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">13.5<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFEVF150\u2011200A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">200A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">4780<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">45000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">17.6<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFEVF150\u2011250A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">250A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">7470<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">70000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">22.5<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFEVF150\u2011300A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">300A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">10760<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">100000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">27.0<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFEVF150\u2011350A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">350A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">15700<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">140000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">30.6<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFEVF150\u2011400A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">400A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">20300<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">180000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">35.2<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFEVF150\u2011500A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">500A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">39000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">120000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">35.0<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFEVF150\u2011600A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">600A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">46000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">140000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">47.0<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFEVF150\u2011700A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">700A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">75000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">220000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">49.0<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFEVF150\u2011800A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">800A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">92000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">280000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">58.0<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 6px;\">GFEVF150\u20111000A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">1000A<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">170000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">510000<\/td>\n<td style=\"border: 1px solid #333; padding: 6px;\">60.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Application Scenarios<\/h2>\n<p>GFEVF150\u2011Series aR Semiconductor DC Power Fuse 125\u2011150VDC 70\u20111000A is built for low\u2011voltage DC new\u2011energy applications: energy\u2011storage battery\u2011pack, DC drives, power converters, rectifier equipment and DC relay backup protection. The aR\u2011class high\u2011speed characteristic provides reliable short\u2011circuit protection for power semiconductor devices under heavy fault\u2011current conditions.<\/p>\n<h2>Installation &amp; Operating Notes<\/h2>\n<ul>\n<li>Bolt\u2011on mounting type; apply correct bolt torque value to avoid poor contact and over\u2011heating risk.<\/li>\n<li>Recommended continuous operating current \u226475% of fuse rated\u2011current; apply temperature\u2011derating factor for ambient temperature over 40\u2103.<\/li>\n<li>For closed\u2011box installation or altitude &gt;2000\u202fm: closed\u2011box environment requires 2%\u20115% current derating per 1000\u202fm altitude rise; open\u2011air installation can normally ignore altitude influence.<\/li>\n<li>Parallel mounting permitted only within dimensional and specification guidelines to achieve higher ampacity.<\/li>\n<li>Do NOT replace fuse under live DC load unless equipped with certified load\u2011break switchgear.<\/li>\n<li>Replace fuse immediately if mechanical damage, crack or deformation occurs on fuse body.<\/li>\n<li>Additional reliability validation test shall be conducted for extremely high\u2011vibration working environments.<\/li>\n<li>Select matched copper conductor cross\u2011section for terminals to control temperature\u2011rise performance.<\/li>\n<\/ul>\n<h2>Packing &amp; Supply<\/h2>\n<p>Standard bulk package. Sample testing support, OEM customization, stable mass\u2011volume supply for energy\u2011storage and power\u2011converter manufacturers. REACH declaration available upon customer request.<\/p>\n<h2>FAQ<\/h2>\n<p><strong>Q: What rating for GFEVF150\u2011Series aR Semiconductor DC Power Fuse 125\u2011150VDC 70\u20111000A?<\/strong><br \/>\nA: Rated 125\u2011150VDC, current range 70\u20111000A, aR semiconductor\u2011protection class, max breaking capacity up to 50kA@150VDC.<\/p>\n<p><strong>Q: What is aR\u2011class operation for this fuse?<\/strong><br \/>\nA: aR class is semiconductor\u2011protecting high\u2011speed fuse class, designed for fast short\u2011circuit protection of power semiconductor devices.<\/p>\n<p><strong>Q: What body sizes are available?<\/strong><br \/>\nA: Two bolt\u2011on body sizes:70\u2011400A and 500\u20111000A for different current grades.<\/p>\n<p><strong>Q: What standards does GFEVF150\u2011Series comply with?<\/strong><br \/>\nA: UL\u2011248\u201113, IEC60269\u20114, CE, RoHS compliant; REACH document available on request.<\/p>\n<p><strong>Q: Main application scenarios for GFEVF150\u2011Series?<\/strong><br \/>\nA: Energy\u2011storage battery\u2011pack, DC drives, power converters, rectifiers and DC relay backup semiconductor short\u2011circuit protection.<\/p>","protected":false},"excerpt":{"rendered":"<pre><code>GFEVF150\u2011Series North\u2011American aR semiconductor DC power fuse, 125\u2011150VDC 70\u20111000A, 50kA interrupting capacity for energy\u2011storage &amp; DC\u2011drive protection.\r\n<\/code><\/pre>","protected":false},"featured_media":16010,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[140],"product_tag":[],"class_list":["post-4103","product","type-product","status-publish","has-post-thumbnail","product_cat-north-american-semiconductor-fuse","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/essfuse.com\/it\/wp-json\/wp\/v2\/product\/4103","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/essfuse.com\/it\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/essfuse.com\/it\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/essfuse.com\/it\/wp-json\/wp\/v2\/comments?post=4103"}],"version-history":[{"count":3,"href":"https:\/\/essfuse.com\/it\/wp-json\/wp\/v2\/product\/4103\/revisions"}],"predecessor-version":[{"id":16011,"href":"https:\/\/essfuse.com\/it\/wp-json\/wp\/v2\/product\/4103\/revisions\/16011"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/essfuse.com\/it\/wp-json\/wp\/v2\/media\/16010"}],"wp:attachment":[{"href":"https:\/\/essfuse.com\/it\/wp-json\/wp\/v2\/media?parent=4103"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/essfuse.com\/it\/wp-json\/wp\/v2\/product_brand?post=4103"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/essfuse.com\/it\/wp-json\/wp\/v2\/product_cat?post=4103"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/essfuse.com\/it\/wp-json\/wp\/v2\/product_tag?post=4103"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}