{"id":4195,"date":"2025-10-21T17:04:19","date_gmt":"2025-10-21T17:04:19","guid":{"rendered":"https:\/\/1clickrepair.in\/ESS\/?post_type=product&#038;p=4195"},"modified":"2026-10-27T00:16:44","modified_gmt":"2026-10-27T00:16:44","slug":"automotive-maxi-blade-fuse-ato-standardmini-car-fuses","status":"publish","type":"product","link":"https:\/\/essfuse.com\/it\/product\/automotive-maxi-blade-fuse-ato-standardmini-car-fuses\/","title":{"rendered":"Automotive Maxi Blade Fuse 20A\u2011100A 32V DC High Current Auto Fuse Link"},"content":{"rendered":"<div>\n<p>Automotive maxi blade fuse is a high-current automotive blade-style overcurrent protection component. This max blade fuse is built for short-circuit and over-current protection for vehicles, electric vehicles, RV, marine equipment and energy-storage power distribution systems, supporting 12V\u201132V DC low voltage circuits.<\/p>\n<h2>Key Features<\/h2>\n<ul>\n<li>Industry\u2011standard MAX blade footprint for matching maxi fuse holders<\/li>\n<li>Low voltage drop and stable electrical performance<\/li>\n<li>Clear time\u2011current characteristic curve for accurate circuit protection matching<\/li>\n<li>High interrupting capacity for severe short\u2011circuit fault<\/li>\n<li>Robust UL94 V\u20112 thermoplastic housing<\/li>\n<li>RoHS compliant and lead\u2011free, suitable for 12\u201132V DC new\u2011energy systems<\/li>\n<\/ul>\n<h2>General Electrical &amp; Mechanical Ratings<\/h2>\n<table style=\"border: 1px solid #000; border-collapse: collapse; width: 100%;\">\n<thead>\n<tr>\n<th style=\"border: 1px solid #000; padding: 9px;\">Item<\/th>\n<th style=\"border: 1px solid #000; padding: 9px;\">Parameter<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Rated Voltage<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">32 V DC<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Interrupting Rating<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">1000 A @ 32 VDC<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Operating Temperature<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u201140 \u2103 ~ +105 \u2103<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Storage Temperature<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u201145 \u2103 ~ +125 \u2103<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Housing Material<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">UL94 V\u20112 Thermoplastic<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Terminal Material<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">Zinc\u2011alloy with surface plating<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Mechanical Dimensions (Unit: mm)<\/h2>\n<table style=\"border: 1px solid #000; border-collapse: collapse; width: 100%;\">\n<thead>\n<tr>\n<th style=\"border: 1px solid #000; padding: 9px;\">Item<\/th>\n<th style=\"border: 1px solid #000; padding: 9px;\">Dimension(mm)<\/th>\n<th style=\"border: 1px solid #000; padding: 9px;\">Tolerance<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Overall Length<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">29.3<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u00b10.3<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Overall Height<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">21.7<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u00b10.3<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Terminal Spacing<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">13.5<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u00b10.5<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Terminal Width<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">8.0<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u00b10.5<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Fuse\u2011element Thickness<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">0.8<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u00b10.05<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Plastic Body Width<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">8.0<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u00b10.3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Time\u2011Current Performance<\/h2>\n<table style=\"border: 1px solid #000; border-collapse: collapse; width: 100%;\">\n<thead>\n<tr>\n<th style=\"border: 1px solid #000; padding: 9px;\">% of Rated Current<\/th>\n<th style=\"border: 1px solid #000; padding: 9px;\">Minimum Blow Time<\/th>\n<th style=\"border: 1px solid #000; padding: 9px;\">Maximum Blow Time<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">110%<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">360000 s<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u2014<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">135%<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">0.750 s<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">600 s<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">200%<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">0.150 s<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">5.0 s<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">350%<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">80 ms<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">500 ms<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">600%<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">0.030 s<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">0.100 s<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Product Specifications Table<\/h2>\n<table style=\"border: 1px solid #000; border-collapse: collapse; width: 100%;\">\n<thead>\n<tr>\n<th style=\"border: 1px solid #000; padding: 9px;\">Model No.<\/th>\n<th style=\"border: 1px solid #000; padding: 9px;\">Rated Current(A)<\/th>\n<th style=\"border: 1px solid #000; padding: 9px;\">Voltage drop(mV)<\/th>\n<th style=\"border: 1px solid #000; padding: 9px;\">Resistance(m\u03a9)<\/th>\n<th style=\"border: 1px solid #000; padding: 9px;\">I\u00b2t (A\u00b2s)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">A020<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">20<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">116<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">10.9<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">160<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">A030<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">30<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">109<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">7.70<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">115<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">A040<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">40<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">102<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">4.80<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">340<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">A050<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">50<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">98<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">3.38<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">520<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">A060<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">60<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">92<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">2.52<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">1080<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">A070<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">70<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">84<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">1.97<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">1510<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">A080<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">80<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">87<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">1.61<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">2280<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">A100<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">100<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">96<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">1.44<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">3310<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><em>Note: Voltage drop &amp; resistance are typical values measured at 23 \u2103 ambient temperature. I\u00b2t is pre\u2011arc I\u00b2t value under standard test conditions.<\/em><\/p>\n<h2>Typical Applications<\/h2>\n<ul>\n<li>Automotive main circuit and auxiliary circuit protection<\/li>\n<li>Truck, commercial vehicle, off\u2011road equipment<\/li>\n<li>EV, RV, marine DC electrical systems<\/li>\n<li>Energy\u2011storage auxiliary power circuits<\/li>\n<li>12V\u201132V DC power distribution systems<\/li>\n<\/ul>\n<h2>FAQ<\/h2>\n<p><strong>Q: What is maxi blade fuse used for?<\/strong><br \/>\nA: Automotive maxi blade fuse is high\u2011current blade\u2011type fuse, mainly for over\u2011current and short\u2011circuit protection of automobiles, trucks, RV, marine, EV and energy\u2011storage 12\u201132V DC power distribution systems.<\/p>\n<p><strong>Q: What is the rated voltage of maxi blade fuse?<\/strong><br \/>\nA: Standard rated voltage is 32V DC. It shall not be used for AC circuits or DC systems exceeding its rated voltage.<\/p>\n<p><strong>Q: What current ratings are available for this maxi blade fuse?<\/strong><br \/>\nA: Available models: A020(20A), A030(30A), A040(40A), A050(50A), A060(60A), A070(70A), A080(80A), A100(100A). Custom specifications are acceptable for bulk orders.<\/p>\n<p><strong>Q: Are maxi blade fuses RoHS compliant and lead\u2011free?<\/strong><br \/>\nA: Yes. All GFEV maxi blade fuses are RoHS\u2011compliant and lead\u2011free to meet global environmental\u2011protection requirements.<\/p>\n<p><strong>Q: Can you provide OEM &amp; ODM service for maxi blade fuse?<\/strong><br \/>\nA: Yes. We support OEM laser marking, custom fuse\u2011element parameters and mass production. Please send your full technical requirements to our sales email for quotation.<\/p>\n<p><strong>Q: How do I choose the correct ampere rating for my project?<\/strong><br \/>\nA: The fuse rated current should be 1.25\u20111.5 times the continuous working current of your circuit. Ambient\u2011temperature derating also needs to be considered. Feel free to contact our engineering team for professional selection support.<\/p>\n<p><strong>Q: What is the interrupting rating of maxi blade fuse?<\/strong><br \/>\nA: Its interrupting rating is 1000A at 32VDC, suitable for short\u2011circuit fault protection in automotive and new\u2011energy DC systems.<\/p>\n<p>Match this automotive maxi blade fuse with our dedicated maxi blade fuse holder for complete and reliable circuit assembly.<\/p>\n<h2>Request Quotation &amp; Technical Support<\/h2>\n<p>Contact our team for datasheet, bulk pricing and custom OEM solution.<\/p>\n<\/div>\n<p><script type=\"application\/ld+json\">\n{\n\"@context\":\"https:\/\/schema.org\",\n\"@type\":\"FAQPage\",\n\"mainEntity\":[\n{\"@type\":\"Question\",\"name\":\"What is maxi blade fuse used for?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Automotive maxi blade fuse is high\u2011current blade\u2011type fuse, mainly for over\u2011current and short\u2011circuit protection of automobiles, trucks, RV, marine, EV and energy\u2011storage 12\u201132V DC power distribution systems.\"}},\n{\"@type\":\"Question\",\"name\":\"What is the rated voltage of maxi blade fuse?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Standard rated voltage is 32V DC. It shall not be used for AC circuits or DC systems exceeding its rated voltage.\"}},\n{\"@type\":\"Question\",\"name\":\"What current ratings are available for this maxi blade fuse?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Available models: A020(20A), A030(30A), A040(40A), A050(50A), A060(60A), A070(70A), A080(80A), A100(100A). Custom specifications are acceptable for bulk orders.\"}},\n{\"@type\":\"Question\",\"name\":\"Are maxi blade fuses RoHS compliant and lead\u2011free?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. All GFEV maxi blade fuses are RoHS\u2011compliant and lead\u2011free to meet global environmental\u2011protection requirements.\"}},\n{\"@type\":\"Question\",\"name\":\"Can you provide OEM & ODM service for maxi blade fuse?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. We support OEM laser marking, custom fuse\u2011element parameters and mass production. Please send your full technical requirements to our sales email for quotation.\"}},\n{\"@type\":\"Question\",\"name\":\"How do I choose the correct ampere rating for my project?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The fuse rated current should be 1.25\u20111.5 times the continuous working current of your circuit. Ambient\u2011temperature derating also needs to be considered. Feel free to contact our engineering team for professional selection support.\"}},\n{\"@type\":\"Question\",\"name\":\"What is the interrupting rating of maxi blade fuse?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Its interrupting rating is 1000A at 32VDC, suitable for short\u2011circuit fault protection in automotive and new\u2011energy DC systems.\"}}\n]\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Automotive maxi blade fuse with 20A\u2011100A ratings, 32V DC high-current blade fuse link. Ideal for vehicle, RV, marine and energy storage DC power distribution protection, RoHS compliant, OEM available.<\/p>","protected":false},"featured_media":3907,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[145,150],"product_tag":[],"class_list":["post-4195","product","type-product","status-publish","has-post-thumbnail","product_cat-automobile-fuse","product_cat-blade-fuse","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/essfuse.com\/it\/wp-json\/wp\/v2\/product\/4195","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/essfuse.com\/it\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/essfuse.com\/it\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/essfuse.com\/it\/wp-json\/wp\/v2\/comments?post=4195"}],"version-history":[{"count":3,"href":"https:\/\/essfuse.com\/it\/wp-json\/wp\/v2\/product\/4195\/revisions"}],"predecessor-version":[{"id":15513,"href":"https:\/\/essfuse.com\/it\/wp-json\/wp\/v2\/product\/4195\/revisions\/15513"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/essfuse.com\/it\/wp-json\/wp\/v2\/media\/3907"}],"wp:attachment":[{"href":"https:\/\/essfuse.com\/it\/wp-json\/wp\/v2\/media?parent=4195"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/essfuse.com\/it\/wp-json\/wp\/v2\/product_brand?post=4195"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/essfuse.com\/it\/wp-json\/wp\/v2\/product_cat?post=4195"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/essfuse.com\/it\/wp-json\/wp\/v2\/product_tag?post=4195"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}