{"id":4128,"date":"2025-10-21T17:03:52","date_gmt":"2025-10-21T17:03:52","guid":{"rendered":"https:\/\/1clickrepair.in\/ESS\/?post_type=product&#038;p=4128"},"modified":"2026-10-28T01:18:51","modified_gmt":"2026-10-28T01:18:51","slug":"gfpvt1000-photovoltaic-fuse-10x38-1000v-solar-fuse","status":"publish","type":"product","link":"https:\/\/essfuse.com\/ru\/product\/gfpvt1000-photovoltaic-fuse-10x38-1000v-solar-fuse\/","title":{"rendered":"GFPVT1000\u201110R series photovoltaic pv fuse 1000VDC 10\u201135A, gPV solar string protection"},"content":{"rendered":"<p><strong><br \/>\n<\/strong><br \/>\n<strong>Dimensions (mm)<\/strong><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-8768 size-full\" src=\"https:\/\/v7-upload.digoodcms.com\/website_193\/2025-06-22\/mceu_74200247211750605411778.png?imageMogr2\/format\/webp\" alt=\"\" width=\"983\" height=\"374\" \/><br \/>\nFerrule xxA-10R Dimensions<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-8768 size-full\" src=\"https:\/\/v7-upload.digoodcms.com\/website_193\/2025-06-22\/mceu_7673374221750605415089.png?imageMogr2\/format\/webp\" alt=\"\" width=\"983\" height=\"374\" \/><\/p>\n<h1>GFPVT1000\u201110R series photovoltaic pv fuse 1000VDC 10\u201135A<\/h1>\n<p>GFPVT1000\u201110R series photovoltaic pv fuse 1000VDC 10\u201135A is a gPV\u2011type solar photovoltaic fuse designed for PV string over\u2011current and short\u2011circuit protection. It delivers excellent DC interruption performance, low I\u00b2t value and low power loss. Supports ferrule\u2011type and axial bolt\u2011on mounting styles, complies with UL\u2011248\u201119 &amp; IEC 60269\u20111\/6 standards. Ideal for solar harness, combiner box and inverter DC\u2011side circuits.<\/p>\n<p><a href=\"https:\/\/essfuse.com\/wp-content\/uploads\/2025\/10\/GFPVT1038-35A-Photovoltaic-Fuses.pdf\">GFPVT1038-35A-Photovoltaic-Fuses<\/a><\/p>\n<h2>Key Features<\/h2>\n<ul>\n<li>Model Series: GFPVT1000\u201110R photovoltaic pv fuse<\/li>\n<li>Rated Voltage: 1000VDC<\/li>\n<li>Current Range: 10A\u201135A<\/li>\n<li>Breaking Capacity: Max 30kA @1000VDC; Min 135% In<\/li>\n<li>Time Constant: \u22642\u00b10.5\u202fms<\/li>\n<li>Low I\u00b2t value, low voltage drop &amp; low power loss<\/li>\n<li>Excellent DC fault\u2011current interruption capability<\/li>\n<li>Two terminal versions: Ferrule\u2011type(xxA\u201110R), Axial bolt\u2011on(xxAP\u201110R)<\/li>\n<li>Able to interrupt low over\u2011current faults from defective PV strings<\/li>\n<li>Compliant: UL\u2011248\u201119, IEC 60269\u20111\/6, RoHS, REACH available on request<\/li>\n<li>Axial bolt\u2011on mounting torque: M5 bolt 4.5\u00b11.0 N\u00b7m<\/li>\n<li>High vibration resistance \u226520g for outdoor solar equipment<\/li>\n<\/ul>\n<h2>General Technical Specifications<\/h2>\n<table style=\"border: 1px solid #333; border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px; width: 42%;\">Product Series<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">GFPVT1000\u201110R Photovoltaic PV Fuse<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Rated Voltage<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">1000\u202fV DC<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Rated Current Range<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">10A\u201135A<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Max Breaking Capacity<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">30kA @1000VDC<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Minimum Breaking Capacity<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">135% In<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Time Constant<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">\u22642\u00b10.5\u202fms<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Terminal Versions<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">Ferrule\u2011type (\u2011A\u201110R), Axial bolt\u2011on (\u2011AP\u201110R)<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Bolt\u2011on Torque(M5)<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">4.5\u00b11.0\u202fN\u00b7m<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Standards Compliance<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">UL\u2011248\u201119, IEC 60269\u20111\/6, RoHS<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Vibration Resistance<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">\u226520g<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 10px;\">Operating Temperature<\/td>\n<td style=\"border: 1px solid #333; padding: 10px;\">\u20115\u2103 ~ +40\u2103(regular);\u201140\u2103~+125\u2103(allowable)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Part Number List &amp; Electrical Parameters<\/h2>\n<table style=\"border: 1px solid #333; border-collapse: collapse; width: 100%; font\u2011size: 14px;\">\n<tbody>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 8px;\">Part Number<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">Rated Current<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">Melting A\u00b2s<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">Clearing A\u00b2s<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">Power Loss\u201180%In(W)<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">Power Loss\u2011100%In(W)<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 8px;\">GFPVT1000\u201110A\u201110R \/\u2011AP\u201110R<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">10A<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">210<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">1175<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">1.1<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">1.5<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 8px;\">GFPVT1000\u201112A\u201110R \/\u2011AP\u201110R<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">12A<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">252<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">1405<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">1.3<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">1.7<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 8px;\">GFPVT1000\u201115A\u201110R \/\u2011AP\u201110R<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">15A<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">315<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">1757<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">1.6<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">2.3<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 8px;\">GFPVT1000\u201116A\u201110R \/\u2011AP\u201110R<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">16A<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">326<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">1780<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">1.6<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">2.3<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 8px;\">GFPVT1000\u201120A\u201110R \/\u2011AP\u201110R<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">20A<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">420<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">2340<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">2.1<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">2.9<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 8px;\">GFPVT1000\u201125A\u201110R \/\u2011AP\u201110R<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">25A<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">525<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">2929<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">2.7<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">3.5<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 8px;\">GFPVT1000\u201130A\u201110R \/\u2011AP\u201110R<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">30A<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">630<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">3515<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">3.2<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">4.2<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 8px;\">GFPVT1000\u201132A\u201110R \/\u2011AP\u201110R<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">32A<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">890<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">3995<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">4.0<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">5.3<\/td>\n<\/tr>\n<tr style=\"border: 1px solid #333;\">\n<td style=\"border: 1px solid #333; padding: 8px;\">GFPVT1000\u201135A\u201110R \/\u2011AP\u201110R<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">35A<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">975<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">4545<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">4.6<\/td>\n<td style=\"border: 1px solid #333; padding: 8px;\">6.2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Application Scenarios<\/h2>\n<p>GFPVT1000\u201110R series photovoltaic pv fuse 1000VDC 10\u201135A is widely applied for grid\u2011tied &amp; off\u2011grid solar\u2011power systems: PV combiner boxes, solar inverter DC input side, photovoltaic string harness, energy\u2011storage DC circuits. It provides reliable gPV\u2011class over\u2011current &amp; short\u2011circuit protection for solar modules and wiring.<\/p>\n<h2>Installation &amp; Operating Notes<\/h2>\n<ul>\n<li>Two terminal styles: ferrule\u2011end for fuse\u2011clip mounting; axial bolt\u2011on for screw fastening; apply 4.5\u00b11.0\u202fN\u00b7m torque for M5 bolt terminals.<\/li>\n<li>Recommended continuous operating current \u226475% of fuse rated\u2011current; apply temperature derating factor when ambient temperature exceeds 40\u2103.<\/li>\n<li>Can be insulated by over\u2011molding or heat\u2011shrink tubing for wire\u2011harness integration.<\/li>\n<li>Do NOT replace fuse under loaded DC circuit conditions unless specially\u2011designed switchgear is fitted.<\/li>\n<li>Replace fuse immediately if mechanical damage or housing crack is observed.<\/li>\n<li>For high\u2011vibration outdoor installations, perform extra reliability validation tests as required.<\/li>\n<\/ul>\n<h2>Packing &amp; Supply<\/h2>\n<p>Standard bulk package. Sample testing support, OEM customization, stable mass\u2011volume supply for solar\u2011energy equipment manufacturers. REACH declaration available upon customer request.<\/p>\n<h2>\u0427\u0430\u0441\u0442\u043e \u0437\u0430\u0434\u0430\u0432\u0430\u0435\u043c\u044b\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b<\/h2>\n<p><strong>Q: What voltage &amp; current for GFPVT1000\u201110R series photovoltaic pv fuse 1000VDC 10\u201135A?<\/strong><br \/>\nA: Rated 1000VDC, current range 10A\u201135A, max breaking capacity up to 30kA@1000VDC.<\/p>\n<p><strong>Q: What standards does GFPVT1000\u201110R comply with?<\/strong><br \/>\nA: Designed according to UL\u2011248\u201119, IEC 60269\u20111\/6, RoHS compliant, REACH document available on request.<\/p>\n<p><strong>Q: What mounting types are available?<\/strong><br \/>\nA: Ferrule\u2011type (\u2011A\u201110R) for fuse\u2011clip; axial bolt\u2011on (\u2011AP\u201110R) for bolt fastening(M5 torque:4.5\u00b11.0N\u00b7m).<\/p>\n<p><strong>Q: Where to use GFPVT1000\u201110R pv fuse?<\/strong><br \/>\nA: Solar PV combiner box, inverter DC\u2011side, photovoltaic string harness and off\u2011grid solar DC\u2011system protection.<\/p>","protected":false},"excerpt":{"rendered":"<div class=\"custom-download-btn-wrapper\">\n<pre><code>GFPVT1000\u201110R series photovoltaic pv fuse, 1000VDC 10\u201135A, 30kA breaking capacity, RoHS compliant, for solar photovoltaic string over\u2011current short\u2011circuit protection.\r\n<\/code><\/pre>\n<\/div>","protected":false},"featured_media":3779,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[142],"product_tag":[],"class_list":["post-4128","product","type-product","status-publish","has-post-thumbnail","product_cat-photovoltaic-fuse","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/essfuse.com\/ru\/wp-json\/wp\/v2\/product\/4128","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/essfuse.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/essfuse.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/essfuse.com\/ru\/wp-json\/wp\/v2\/comments?post=4128"}],"version-history":[{"count":3,"href":"https:\/\/essfuse.com\/ru\/wp-json\/wp\/v2\/product\/4128\/revisions"}],"predecessor-version":[{"id":15832,"href":"https:\/\/essfuse.com\/ru\/wp-json\/wp\/v2\/product\/4128\/revisions\/15832"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/essfuse.com\/ru\/wp-json\/wp\/v2\/media\/3779"}],"wp:attachment":[{"href":"https:\/\/essfuse.com\/ru\/wp-json\/wp\/v2\/media?parent=4128"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/essfuse.com\/ru\/wp-json\/wp\/v2\/product_brand?post=4128"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/essfuse.com\/ru\/wp-json\/wp\/v2\/product_cat?post=4128"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/essfuse.com\/ru\/wp-json\/wp\/v2\/product_tag?post=4128"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}