{"id":4222,"date":"2025-02-04T10:48:28","date_gmt":"2025-02-04T10:48:28","guid":{"rendered":"https:\/\/1clickrepair.in\/ESS\/?post_type=product&#038;p=4222"},"modified":"2026-10-28T11:21:23","modified_gmt":"2026-10-28T11:21:23","slug":"500v-dc-fast-acting-fuse-gfevt500-a-74e-500a-1800a-for-ev-ess","status":"publish","type":"product","link":"https:\/\/essfuse.com\/ru\/product\/500v-dc-fast-acting-fuse-gfevt500-a-74e-500a-1800a-for-ev-ess\/","title":{"rendered":"GFEVT500\u2011A\u201174E Fast\u2011Acting DC Fuse 500\u20111800A 500VDC | EssFuse"},"content":{"rendered":"<p>Dimensions (mm)<br \/>\n<img decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/v7-upload.digoodcms.com\/website_193\/2025-07-08\/GFEVT500-A-74E-High-Speed-Fuse-500A-1800A-500VDC-2.png?imageMogr2\/format\/webp\" \/><\/p>\n<div>\n<p><strong>GFEVT500\u2011A\u201174E Series Square\u2011Body Fast\u2011Acting Fuse<\/strong> is Size\u20113# square\u2011body fast\u2011acting <strong>high speed dc fuse<\/strong> specially designed for heavy\u2011duty new\u2011energy DC circuits. aR performance class, rated 500\u20111800A 500VDC, max 50kA interrupting capacity, minimum breaking current \u22655In, time constant \u22645\u202fms. Adopts flush\u2011end contact structure. Features low watt\u2011loss, superior cycling capability, outstanding anti\u2011vibration &amp; shock\u2011resistance \u226520g. RoHS compliant, REACH documentation available upon request. Widely used for large\u2011capacity battery pack, BESS energy\u2011storage cabinets and DC relay backup short\u2011circuit protection.<\/p>\n<p><a href=\"https:\/\/essfuse.com\/wp-content\/uploads\/2025\/02\/GFEVT500-A-74E-Series.-500-1800A-500Vdc-fast-acting-fuse.pdf\">GFEVT500-A-74E-Series.-500-1800A-500Vdc-fast-acting-fuse<\/a><\/p>\n<h2>Product At A Glance<\/h2>\n<table style=\"border: 1px solid #000; border-collapse: collapse; width: 100%;\">\n<thead>\n<tr>\n<th style=\"border: 1px solid #000; padding: 9px;\">Item<\/th>\n<th style=\"border: 1px solid #000; padding: 9px;\">Parameter<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Product Series<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u2011A\u201174E Series, Size\u20113# Square\u2011Body Fast\u2011Acting Fuse<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Current Range<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">500A\u20111800A<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Rated Voltage<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">500VDC<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Interrupting Capacity<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">50kA @500VDC; Minimum breaking current \u22655In<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Time Constant<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">\u22645\u202fms<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Performance Class<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">aR (Semiconductor \/ power\u2011device backup short\u2011circuit protection)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Contact Type<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">Flush\u2011end contact<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Standards<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">UL 248.1, UL248.13; IEC 60269\u20111, IEC 60269\u20114<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">Compliance<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">RoHS compliant, REACH declaration available upon request<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Electrical Data @50kA 500VDC<\/h2>\n<table style=\"border: 1px solid #000; border-collapse: collapse; width: 100%;\">\n<thead>\n<tr>\n<th style=\"border: 1px solid #000; padding: 9px;\">Part Number<\/th>\n<th style=\"border: 1px solid #000; padding: 9px;\">Rated Amps<\/th>\n<th style=\"border: 1px solid #000; padding: 9px;\">Melting A\u00b2s<\/th>\n<th style=\"border: 1px solid #000; padding: 9px;\">Clearing A\u00b2t<\/th>\n<th style=\"border: 1px solid #000; padding: 9px;\">100% Power Loss(W)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u2011500A\u201174E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">500A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">12290<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">85500<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">95<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u2011550A\u201174E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">550A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">16900<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">121500<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">105<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u2011630A\u201174E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">630A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">26970<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">189000<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">115<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u2011700A\u201174E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">700A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">38715<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">270000<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">120<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u2011800A\u201174E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">800A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">60450<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">418500<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">130<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u2011900A\u201174E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">900A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">87000<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">603000<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">138<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u20111000A\u201174E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">1000A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">121800<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">850500<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">145<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u20111100A\u201174E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">1100A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">165300<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">1170000<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">165<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u20111250A\u201174E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">1250A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">252300<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">1755000<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">180<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">GFEVT500\u20111400A\u201174E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">1400A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">322500<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">2205000<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">190<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">*GFEVT500\u20111500A\u201174E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">1500A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">400200<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">2790000<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">200<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">*GFEVT500\u20111600A\u201174E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">1600A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">505600<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">3510000<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">230<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 9px;\">*GFEVT500\u20111800A\u201174E<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">1800A<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">765600<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">4925000<\/td>\n<td style=\"border: 1px solid #000; padding: 9px;\">260<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><small>*Note: Models marked asterisk require prior communication with factory for availability.<\/small><\/p>\n<h2>Key Features &amp; Benefits<\/h2>\n<ul>\n<li>aR\u2011class Size\u20113# square\u2011body fast\u2011acting DC fuse, low I\u00b2t characteristic, up to ten\u2011times faster opening under high fault\u2011current for semiconductor backup short\u2011circuit protection<\/li>\n<li>50kA high interrupting capacity @500VDC, time constant \u22645\u202fms, minimum breaking current \u22655In<\/li>\n<li>Flush\u2011end contact construction; higher ampacity within compact dimensional outline, saving cabinet space and reducing overall system cost<\/li>\n<li>Low watt\u2011loss design, superior cycling performance, excellent thermal\u2011shock &amp; wide\u2011range temperature tolerance<\/li>\n<li>High mechanical reliability, \u226520g anti\u2011vibration and shock\u2011resistance for harsh industrial &amp; energy\u2011storage cabinet environments<\/li>\n<li>Supports full\u2011parameter derating correction for high\u2011temperature, high\u2011altitude and forced\u2011air\u2011cooling operating\u2011conditions<\/li>\n<li>Complies with UL 248.1\u201113 &amp; IEC 60269\u20111\u20114; RoHS compliant, REACH documents available for export\u2011oriented projects<\/li>\n<\/ul>\n<h2>Application Overview<\/h2>\n<p>GFEVT500\u2011A\u201174E series square\u2011body high\u2011speed fuses are purpose\u2011built for large\u2011capacity new\u2011energy DC\u2011equipment. Mainly deployed for high\u2011power battery pack protection, BESS energy\u2011storage cabinets and DC relay backup short\u2011circuit protection.<\/p>\n<p><strong>Critical Tip:<\/strong> Long\u2011term continuous operating\u2011current shall \u226475% of fuse rated\u2011current. Apply temperature\u2011altitude\u2011forced\u2011air derating\u2011factors for enclosed\u2011cabinet installation. Always disconnect DC power before fuse replacement.<\/p>\n<h2>Installation &amp; Operating Notes<\/h2>\n<ol>\n<li>Select proper copper conductor cross\u2011section following datasheet specification to guarantee stable contact performance.<\/li>\n<li>Long\u2011term continuous working\u2011current cannot exceed 75% of nominal fuse ampere\u2011rating.<\/li>\n<li>Carry\u2011out current\u2011derating when ambient\u2011temperature\uff1e40\u2103 or installation\u2011altitude\uff1e2000\u202fm under closed\u2011cabinet environment.<\/li>\n<li>Derating is also required for forced\u2011air cooling application, refer to official derating curves for correction\u2011coefficient.<\/li>\n<li>Permitted for vertical, horizontal or inclined mounting; avoid gravity\u2011vibration impact affecting contact reliability.<\/li>\n<li>Discard and replace fuse immediately if mechanical\u2011damage occurs; avoid live\u2011load fuse\u2011replacement unless equipment\u2011design explicitly permits.<\/li>\n<\/ol>\n<h2>Typical Applications<\/h2>\n<ul>\n<li>Large\u2011capacity new\u2011energy battery\u2011pack over\u2011current &amp; short\u2011circuit backup\u2011protection<\/li>\n<li>BESS utility\u2011scale energy\u2011storage\u2011system high\u2011power DC\u2011feeder protection<\/li>\n<li>DC relay and power\u2011semiconductor\u2011device backup short\u2011circuit\u2011protection<\/li>\n<li>Heavy\u2011duty 500VDC new\u2011energy converter\u2011inverter internal DC\u2011side protection<\/li>\n<li>High\u2011current industrial energy\u2011storage power\u2011distribution assemblies<\/li>\n<\/ul>\n<p>Pair GFEVT500\u2011A\u201174E series fuse with our <a href=\"https:\/\/essfuse.com\/ru\/product-category\/fuse\u2011holders\/\">matching heavy\u2011duty semiconductor fuse holders<\/a> for complete heavy\u2011current DC\u2011protection assembly.<\/p>\n<h2>Safety Reminders<\/h2>\n<ul>\n<li>Disconnect all DC\u2011power before servicing or changing fuses. <strong>Strictly prohibit live\u2011line 500VDC high\u2011voltage operation.<\/strong><\/li>\n<li>Observe 75% rated\u2011current continuous\u2011working derating\u2011rule; extra\u2011derating required for high\u2011temperature \/ high\u2011altitude enclosed\u2011cabinet installation.<\/li>\n<li>Select fuse breaking\u2011capacity higher than prospective short\u2011circuit\u2011current of your system.<\/li>\n<li>Refer to official datasheet for I\u2011t curve, temperature\u2011altitude\u2011derating\u2011curves and dimension drawings before bulk\u2011procurement.<\/li>\n<li>Mechanically\u2011damaged fuse\u2011unit must be discarded and replaced immediately.<\/li>\n<li>Asterisk\u2011marked high\u2011current variants require factory pre\u2011confirmation before ordering.<\/li>\n<\/ul>\n<h2>\u0427\u0430\u0441\u0442\u043e \u0437\u0430\u0434\u0430\u0432\u0430\u0435\u043c\u044b\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b<\/h2>\n<p><strong>Q: What is GFEVT500\u2011A\u201174E series high\u2011speed fuse?<\/strong><br \/>\nA: GFEVT500\u2011A\u201174E is Size\u20113# square\u2011body aR\u2011class fast\u2011acting DC fuse, rating 500\u20111800A @500VDC, 50kA interrupting\u2011capacity with flush\u2011end contact. Designed for large\u2011capacity battery\u2011pack and BESS energy\u2011storage backup\u2011protection, RoHS compliant, REACH available upon request.<\/p>\n<p><strong>Q: What is the rule for continuous\u2011current operation?<\/strong><br \/>\nA: Long\u2011term operating\u2011current must be \u226475% of fuse rated\u2011current. Additional derating shall be applied for high\u2011temperature, high\u2011altitude enclosed\u2011cabinet and forced\u2011air\u2011cooling scenarios.<\/p>\n<p><strong>Q: What special notes for asterisk\u2011marked part\u2011numbers?<\/strong><br \/>\nA: Models with asterisk (*) such as 1500A,1600A,1800A need prior technical communication with factory for lead\u2011time and availability confirmation.<\/p>\n<p><strong>Q: What standards does this series comply with?<\/strong><br \/>\nA: Reference standards UL 248.1, UL248.13, IEC 60269\u20111, IEC 60269\u20114; RoHS compliant, REACH declaration can be provided for overseas\u2011export\u2011projects.<\/p>\n<p><strong>Q: Where is GFEVT500\u2011A\u201174E commonly used?<\/strong><br \/>\nA: Applied for large\u2011capacity battery\u2011pack protection, utility\u2011scale BESS cabinets, DC\u2011relay backup\u2011protection and heavy\u2011duty 500VDC converter\u2011inverter DC\u2011side circuits.<\/p>\n<h2>Request Quotation &amp; Technical Support<\/h2>\n<p>Please provide target part\u2011number, order\u2011quantity, system short\u2011circuit\u2011current, ambient\u2011temperature and altitude\u2011conditions. For asterisk\u2011marked high\u2011current models, please confirm availability in advance. Our engineering\u2011team can deliver full datasheet, bulk\u2011price quotation and component\u2011selection\u2011guidance for large\u2011scale battery\u2011energy\u2011storage DC\u2011protection\u2011projects.<\/p>\n<p style=\"font\u2011size: 0.9em; color: #555;\">GFEVT500\u2011A\u201174E Series High\u2011Speed Fuse \u00b7 EssFuse. Confirm datasheet I\u2011t, derating and dimension specs before mass\u2011production.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<div id=\"downloadAttachmentBtn\" class=\"custom-download-btn-wrapper\">EssFuse GFEVT500\u2011A\u201174E series fast\u2011acting square\u2011body DC fuse links,rated 500VDC,500A\u20111800A,aR class,50kA interrupting capacity,designed for battery pack,energy\u2011storage and DC relay backup protection.UL248.13,IEC60269.4,RoHS compliant,shock\u2011vibration resistant.Size:3#,flush\u2011end contact.*1500\u20111800A need factory pre\u2011communication.<\/div>","protected":false},"featured_media":3966,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[139],"product_tag":[],"class_list":["post-4222","product","type-product","status-publish","has-post-thumbnail","product_cat-square-high-speed-fuse","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/essfuse.com\/ru\/wp-json\/wp\/v2\/product\/4222","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/essfuse.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/essfuse.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/essfuse.com\/ru\/wp-json\/wp\/v2\/comments?post=4222"}],"version-history":[{"count":3,"href":"https:\/\/essfuse.com\/ru\/wp-json\/wp\/v2\/product\/4222\/revisions"}],"predecessor-version":[{"id":16321,"href":"https:\/\/essfuse.com\/ru\/wp-json\/wp\/v2\/product\/4222\/revisions\/16321"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/essfuse.com\/ru\/wp-json\/wp\/v2\/media\/3966"}],"wp:attachment":[{"href":"https:\/\/essfuse.com\/ru\/wp-json\/wp\/v2\/media?parent=4222"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/essfuse.com\/ru\/wp-json\/wp\/v2\/product_brand?post=4222"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/essfuse.com\/ru\/wp-json\/wp\/v2\/product_cat?post=4222"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/essfuse.com\/ru\/wp-json\/wp\/v2\/product_tag?post=4222"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}