{"id":4237,"date":"2025-02-04T10:49:28","date_gmt":"2025-02-04T10:49:28","guid":{"rendered":"https:\/\/1clickrepair.in\/ESS\/?post_type=product&#038;p=4237"},"modified":"2026-10-29T10:58:00","modified_gmt":"2026-10-29T10:58:00","slug":"gfhev1-k-series-high-speed-fuse-250v-dc","status":"publish","type":"product","link":"https:\/\/essfuse.com\/tl\/product\/gfhev1-k-series-high-speed-fuse-250v-dc\/","title":{"rendered":"GFHEV1-K Series High Speed Fuse | 200A-450A 250V DC Fuse"},"content":{"rendered":"<pre><code>GFHEV1\u2011K Series High Speed Fuse is a square\u2011body aR fast\u2011acting DC fuse designed for industrial energy storage system overcurrent and short\u2011circuit protection.\r\n<\/code><\/pre>\n<p>Dimensions (mm)<br \/>\n<img decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/v7-upload.digoodcms.com\/website_193\/2025-07-08\/1-5.png?imageMogr2\/format\/webp\" \/><br \/>\nGFHEV1-xxxK<br \/>\n<img decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/v7-upload.digoodcms.com\/website_193\/2025-07-08\/2-5.png?imageMogr2\/format\/webp\" \/><br \/>\n<!-- ==========\u4e3b\u89c4\u683c\u5b9e\u7ebf\u8868\u683c ========== --><\/p>\n<table style=\"width: 100%; border-collapse: collapse; margin: 20px 0;\" border=\"1\" cellspacing=\"0\" cellpadding=\"8\">\n<tbody>\n<tr>\n<td><strong>Series Model<\/strong><\/td>\n<td>GFHEV1\u2011K Series High\u2011Speed Fuse<\/td>\n<\/tr>\n<tr>\n<td><strong>Rated Voltage<\/strong><\/td>\n<td>250\u202fV DC<\/td>\n<\/tr>\n<tr>\n<td><strong>Rated Current Range<\/strong><\/td>\n<td>200A\u2011450A<\/td>\n<\/tr>\n<tr>\n<td><strong>Utilization Class<\/strong><\/td>\n<td>aR (Fast\u2011acting for semiconductor protection)<\/td>\n<\/tr>\n<tr>\n<td><strong>Interrupting Capacity<\/strong><\/td>\n<td>50\u202fkA @250Vdc (L\/R \u22645ms); Minimum breaking current \u22655In<\/td>\n<\/tr>\n<tr>\n<td><strong>Body Size<\/strong><\/td>\n<td>Size #1 Square\u2011body fuse\u2011link<\/td>\n<\/tr>\n<tr>\n<td><strong>Indicator Version<\/strong><\/td>\n<td>K\u2011version: with fuse indicator; KN\u2011version: without indicator<\/td>\n<\/tr>\n<tr>\n<td><strong>Standards &amp; Compliance<\/strong><\/td>\n<td>Refer to UL\u202f248.13, RoHS Compliant<\/td>\n<\/tr>\n<tr>\n<td><strong>Operating Ambient Temperature<\/strong><\/td>\n<td>\u201140\u202f\u00b0C ~ +85\u202f\u00b0C<\/td>\n<\/tr>\n<tr>\n<td><strong>Typical Application<\/strong><\/td>\n<td>Industrial ESS, DC power system, semiconductor device over\u2011current protection<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><!-- ==========\u5206\u578b\u53f7\u7535\u6c14\u53c2\u6570\u5b9e\u7ebf\u8868\u683c ========== --><\/p>\n<table style=\"width: 100%; border\u2011collapse: collapse; margin: 20px 0;\" border=\"1\" cellspacing=\"0\" cellpadding=\"8\">\n<thead>\n<tr>\n<th>Part Number<\/th>\n<th>Rated Current(A)<\/th>\n<th>Body Size<\/th>\n<th>Melting A\u00b2s<\/th>\n<th>Clearing A\u00b2t<\/th>\n<th>100% Power Loss(W)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>GFHEV1\u2011200K<\/td>\n<td>200<\/td>\n<td>#1<\/td>\n<td>11,590<\/td>\n<td>138,180<\/td>\n<td>18<\/td>\n<\/tr>\n<tr>\n<td>GFHEV1\u2011250K<\/td>\n<td>250<\/td>\n<td>#1<\/td>\n<td>19,850<\/td>\n<td>233,940<\/td>\n<td>20<\/td>\n<\/tr>\n<tr>\n<td>GFHEV1\u2011275K<\/td>\n<td>275<\/td>\n<td>#1<\/td>\n<td>28,450<\/td>\n<td>335,580<\/td>\n<td>23<\/td>\n<\/tr>\n<tr>\n<td>GFHEV1\u2011315K<\/td>\n<td>315<\/td>\n<td>#1<\/td>\n<td>39,490<\/td>\n<td>478,690<\/td>\n<td>25<\/td>\n<\/tr>\n<tr>\n<td>GFHEV1\u2011350K<\/td>\n<td>350<\/td>\n<td>#1<\/td>\n<td>50,540<\/td>\n<td>616,350<\/td>\n<td>26<\/td>\n<\/tr>\n<tr>\n<td>GFHEV1\u2011400K<\/td>\n<td>400<\/td>\n<td>#1<\/td>\n<td>68,980<\/td>\n<td>848,350<\/td>\n<td>28<\/td>\n<\/tr>\n<tr>\n<td>GFHEV1\u2011450K<\/td>\n<td>450<\/td>\n<td>#1<\/td>\n<td>101,600<\/td>\n<td>1,290,200<\/td>\n<td>39<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><!-- ==========\u7f51\u9875\u53ef\u89c6\u5316FAQ ========== --><\/p>\n<div style=\"margin: 30px 0;\">\n<h3>Frequently Asked Questions<\/h3>\n<div style=\"border: 1px solid #ddd; margin\u2011bottom: 8px;\">\n<div style=\"background: #f7f7f7; padding: 12px 16px; font\u2011weight: bold;\">Q: What is difference between K and KN suffix for GFHEV1\u2011K series?<\/div>\n<div style=\"padding: 12px 16px;\">A: Suffix K means built\u2011in fuse blow indicator; KN means without indicator function. Both share identical electrical performance.<\/div>\n<\/div>\n<div style=\"border: 1px solid #ddd; margin\u2011bottom: 8px;\">\n<div style=\"background: #f7f7f7; padding: 12px 16px; font\u2011weight: bold;\">Q: What application for GFHEV1\u2011K square\u2011body fuse\u2011link?<\/div>\n<div style=\"padding: 12px 16px;\">A: This aR fast\u2011acting fuse\u2011link is mainly designed for industrial ESS energy\u2011storage cabinets and semiconductor DC\u2011circuit short\u2011circuit protection under 250\u202fV DC.<\/div>\n<\/div>\n<div style=\"border: 1px solid #ddd; margin\u2011bottom: 8px;\">\n<div style=\"background: #f7f7f7; padding: 12px 16px; font\u2011weight: bold;\">Q: What is interrupting rating of GFHEV1\u2011K series?<\/div>\n<div style=\"padding: 12px 16px;\">A: Max interrupting capacity is 50\u202fkA at 250\u202fV DC under L\/R \u22645ms condition; minimum breaking current \u22655In.<\/div>\n<\/div>\n<div style=\"border: 1px solid #ddd; margin\u2011bottom: 8px;\">\n<div style=\"background: #f7f7f7; padding: 12px 16px; font\u2011weight: bold;\">Q: What standards comply with GFHEV1\u2011K fuse?<\/div>\n<div style=\"padding: 12px 16px;\">A: It refers to UL\u202f248.13 standard and fully meets RoHS environmental\u2011compliance requirements.<\/div>\n<\/div>\n<\/div>\n<p><!-- ==========Product + FAQPage JSON\u2011LD \u8c37\u6b4c\u5bcc\u7ed3\u679c \/ AI\u2011Overview\u6293\u53d6 ========== --><a href=\"https:\/\/essfuse.com\/wp-content\/uploads\/2025\/02\/GFHEV1-K-200A-450A-250V-Fast-acting-fuse.pdf\">GFHEV1-K 200A-450A 250V Fast-acting fuse<\/a><br \/>\n<script type=\"application\/ld+json\">\n[\n{\n\"@context\":\"https:\/\/schema.org\/\",\n\"@type\":\"Product\",\n\"name\":\"GFHEV1\u2011K Series High Speed Fuse\",\n\"sku\":\"GFHEV1\u2011K Series\",\n\"mpn\":\"GFHEV1\u2011K\",\n\"brand\":{\"@type\":\"Brand\",\"name\":\"ESSFUSE\"},\n\"manufacturer\":{\"@type\":\"Organization\",\"name\":\"Dongguan GongFu Electronics Co.,Ltd\"},\n\"description\":\"GFHEV1\u2011K series square\u2011body aR fast\u2011acting DC fuse\u2011link,200\u2011450A,250Vdc,50kA interrupting capacity for industrial ESS semiconductor protection,K \/ KN indicator options,UL248.13 & RoHS compliant.\",\n\"offers\":{\"@type\":\"AggregateOffer\",\"availability\":\"https:\/\/schema.org\/InStock\",\"offerCount\":1},\n\"additionalProperty\":[\n{\"@type\":\"PropertyValue\",\"name\":\"Rated DC Voltage\",\"value\":\"250V DC\"},\n{\"@type\":\"PropertyValue\",\"name\":\"Rated Current Range\",\"value\":\"200A\u2011450A\"},\n{\"@type\":\"PropertyValue\",\"name\":\"Utilization Category\",\"value\":\"aR Fast\u2011acting semiconductor fuse\u2011link\"},\n{\"@type\":\"PropertyValue\",\"name\":\"Interrupting Capacity\",\"value\":\"50kA @250Vdc(L\/R \u22645ms)\"},\n{\"@type\":\"PropertyValue\",\"name\":\"Body Size\",\"value\":\"Size #1 square\u2011body fuse\u2011link\"},\n{\"@type\":\"PropertyValue\",\"name\":\"Indicator Option\",\"value\":\"K(with indicator), KN(without indicator)\"},\n{\"@type\":\"PropertyValue\",\"name\":\"Compliance\",\"value\":\"UL248.13 referenced, RoHS compliant\"},\n{\"@type\":\"PropertyValue\",\"name\":\"Application\",\"value\":\"Industrial ESS, DC power system, semiconductor protection\"}\n]\n},\n{\n\"@context\":\"https:\/\/schema.org\",\n\"@type\":\"FAQPage\",\n\"mainEntity\":[\n{\n\"@type\":\"Question\",\n\"name\":\"What is difference between K and KN suffix for GFHEV1\u2011K series?\",\n\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Suffix K means built\u2011in fuse blow indicator; KN means without indicator function. Both share identical electrical performance.\"}\n},\n{\n\"@type\":\"Question\",\n\"name\":\"What application for GFHEV1\u2011K square\u2011body fuse\u2011link?\",\n\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"This aR fast\u2011acting fuse\u2011link is mainly designed for industrial ESS energy\u2011storage cabinets and semiconductor DC\u2011circuit short\u2011circuit protection under 250\u202fV DC.\"}\n},\n{\n\"@type\":\"Question\",\n\"name\":\"What is interrupting rating of GFHEV1\u2011K series?\",\n\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Max interrupting capacity is 50\u202fkA at 250\u202fV DC under L\/R \u22645ms condition; minimum breaking current \u22655In.\"}\n},\n{\n\"@type\":\"Question\",\n\"name\":\"What standards comply with GFHEV1\u2011K fuse?\",\n\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"It refers to UL\u202f248.13 standard and fully meets RoHS environmental\u2011compliance requirements.\"}\n}\n]\n}\n]\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<pre><code>GFHEV1\u2011K Series square\u2011body high\u2011speed aR fast\u2011acting DC fuse,200\u2011450A 250Vdc,50kA breaking capacity for industrial ESS semiconductor protection. Available K(with indicator) \/ KN(without indicator). UL248.13 &amp; RoHS compliant.\r\n<\/code><\/pre>\n<div><\/div>\n<div class=\"custom-download-btn-wrapper\">\n&nbsp;<\/p>\n<\/div>","protected":false},"featured_media":16421,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[139],"product_tag":[],"class_list":["post-4237","product","type-product","status-publish","has-post-thumbnail","product_cat-square-high-speed-fuse","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/essfuse.com\/tl\/wp-json\/wp\/v2\/product\/4237","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/essfuse.com\/tl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/essfuse.com\/tl\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/essfuse.com\/tl\/wp-json\/wp\/v2\/comments?post=4237"}],"version-history":[{"count":4,"href":"https:\/\/essfuse.com\/tl\/wp-json\/wp\/v2\/product\/4237\/revisions"}],"predecessor-version":[{"id":16419,"href":"https:\/\/essfuse.com\/tl\/wp-json\/wp\/v2\/product\/4237\/revisions\/16419"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/essfuse.com\/tl\/wp-json\/wp\/v2\/media\/16421"}],"wp:attachment":[{"href":"https:\/\/essfuse.com\/tl\/wp-json\/wp\/v2\/media?parent=4237"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/essfuse.com\/tl\/wp-json\/wp\/v2\/product_brand?post=4237"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/essfuse.com\/tl\/wp-json\/wp\/v2\/product_cat?post=4237"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/essfuse.com\/tl\/wp-json\/wp\/v2\/product_tag?post=4237"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}