New Energy Fuse Holder‑H10MF 10×38 Fuse Holder,1000VDC,50A(Bolt)/30A(Clamp),UL94 V‑0 PBT+PC

Category:
H10MF 10×38 new‑energy fuse holder, matches GFEFUSE® H10H fuse. 1000VDC,50A(bolt)/30A(clamp), PBT+PC UL94 V‑0 for renewable energy systems.

Product Selection

Support in finding suitable fuses for your application.

Technical Support

Contact our team for product details and technical guidance.

Project Enquiries

Discuss your requirements, quantities, and purchasing plans.

Need a Fuse for Your Project?

Share your requirements with us for product guidance and a quotation.

H10MF 10×38 New‑Energy Fuse Holder delivers superior over‑current protection for modern renewable‑energy infrastructure, ensuring equipment safety, reliable operation and extended system service life. This heavy‑duty new energy fuse holder is specially designed for 10×38 mm cylindrical fuses (matched with GFEFUSE® H10H fuse). Rated 1000VDC; 50A for bolt‑terminal version and 30A for clamp‑terminal version. Constructed with PBT base and PC top‑cover, UL94 V‑0 flammability rating, maximum working temperature up to 125 °C. Suitable for photovoltaic, energy‑storage and various new‑energy DC‑protection assemblies.

Product At A Glance

ItemParameter
Product ModelH10MF 10×38 New‑Energy Fuse Holder
Matching Fuse10×38 mm fuse ( H10H matching fuse)
Rated Voltage1000 VDC
Rated CurrentUp to 50A (bolt), 30A (clamp)
Dielectric Strength>1200 V
Recommended Torque2.3 N·m (20 in‑LBS)
Wire Range14‑7 AWG (1.6‑8.42 mm²)
Clip / TerminalTinned copper alloy (M5 screw)
Screw & External Pressing PlateGalvanized steel
Base MaterialThermoplastic (PBT)
Top‑cover MaterialPC
Max Working TemperatureUp to 125 °C
Material FlammabilityUL 94 V‑0

Key Features

  • Optimized for 10×38 mm cylindrical fuses, perfectly compatible with GFEFUSE® H10H fuse for renewable‑energy DC‑circuit protection
  • Dual‑version options: bolt‑terminal up to 50A; clamp‑terminal up to 30A, rated for 1000VDC new‑energy systems
  • High dielectric strength>1200V; supports 14‑7 AWG wide‑range wire connection with M5 tinned‑copper‑alloy terminals
  • Base:PBT; Top‑cover:PC, UL94 V‑0 flame‑retardant, continuous working temperature up to 125 °C for harsh cabinet‑environment
  • Galvanized‑steel screw and pressing‑plate, anti‑corrosion and stable clamping performance
  • Strict 2.3 N·m installation‑torque specification for preventing over‑heating under full‑load condition
  • Compact structure for combiner‑box, inverter cabinet and energy‑storage cabinet internal assembly

Application Overview

H10MF new‑energy fuse holder is engineered for modern renewable‑energy infrastructure. It must be assembled with qualified 10×38 mm DC‑special fuses (GFEFUSE® H10H).

Critical Tip: Distinguish bolt‑version (max 50A) and clamp‑version (max30A). Apply recommended 2.3 N·m torque; select fuse breaking capacity higher than system short‑circuit current.

Installation Steps

  1. Completely cut‑off DC power before installation and fuse‑replacement work.
  2. Securely mount H10MF fuse holder inside equipment cabinet.
  3. Strip cable and connect conductors to M5 terminals, tighten screw to 2.3 N·m (20 in‑LBS) torque.
  4. Insert matched 10×38 mm qualified DC‑rated fuse (® H10H).
  5. Close protective top‑cover and double‑check terminal tightness.
  6. Contact sales for bulk‑order custom‑requirements.

Typical Applications

  • Photovoltaic combiner‑box string over‑current & short‑circuit protection
  • Battery Energy Storage System (BESS) DC‑side circuit protection
  • Renewable‑energy inverter cabinet internal DC‑distribution protection
  • New‑energy charging‑pile auxiliary DC‑circuit protection
  • General 1000VDC industrial new‑energy power‑distribution assemblies

Pair this H10MF fuse holder with our H10H 10×38 mm fuses for complete renewable‑energy DC‑protection solution.

Safety Reminders

  • Disconnect all DC power before servicing. Strictly prohibit live‑line 1000VDC high‑voltage operation.
  • Follow 2.3 N·m(20 in‑LBS) torque for M5 terminals; improper torque will generate over‑heat at full‑load.
  • Bolt‑type max 50A; clamp‑type max30A. Do not exceed respective current‑rating of each version.
  • Only use DC‑specialized 10×38 mm fuses ( H10H). General‑purpose AC fuses cannot be used for 1000VDC PV systems.
  • Refer to official datasheet for dimension and full‑spec data before mass‑procurement.

Preguntas frecuentes

Q: What fuse matches H10MF fuse holder?
A: H10MF fits 10×38 mm cylindrical fuses, matched model:  H10H. Bolt‑terminal version max 50A; clamp‑terminal version max30A at 1000VDC.

Q: What is current rating difference between bolt‑version and clamp‑version?
A: Bolt‑terminal: up to 50A; clamp‑terminal: up to 30A. Both versions rated 1000VDC, dielectric strength>1200V.

Q: What material is H10MF made of?
A: Base:PBT thermoplastic; Top‑cover:PC; clip/terminal: tinned‑copper‑alloy M5 screw; screw & pressing‑plate: galvanized‑steel; flammability UL94 V‑0, max working temp 125 °C.

Q: What torque and wire range should I follow?
A: Recommended torque 2.3 N·m (20 in‑LBS); applicable wire range:14‑7 AWG (1.6‑8.42 mm²).

Q: Where is H10MF new‑energy fuse holder applied?
A: Widely for PV combiner‑boxes, energy‑storage cabinets, inverter cabinets and other 1000VDC renewable‑energy infrastructure DC‑protection circuits.

Request Quotation & Technical Support

Please provide order quantity and your new‑energy system electrical‑parameters. Our engineering team can provide datasheet, bulk‑price quotation and component‑selection guidance for your renewable‑energy DC‑protection‑projects.

H10MF 10×38 New‑Energy Fuse Holder · EssFuse. Verify datasheet specs before mass‑production.