High‑Speed Fuse GFEVT1500‑S‑105ES 400‑2000A 1500VDC Square Fuse

GFEVT1500‑S‑105ES square high‑speed 1500Vdc aR fuse,400‑2000A fast‑acting DC fuse,50kA interrupt rating,UL248‑13 & IEC60269‑4 certified for energy‑storage,wind‑power and battery‑pack short‑circuit protection.

Product Selection

Support in finding suitable fuses for your application.

Technical Support

Contact our team for product details and technical guidance.

Project Enquiries

Discuss your requirements, quantities, and purchasing plans.

Need a Fuse for Your Project?

Share your requirements with us for product guidance and a quotation.

GFEVT1500‑S‑105ES Square High‑Speed Fuse 400‑2000A 1500VDC DC Energy‑Storage Fuse

Our High‑Speed Fuse model GFEVT1500‑S‑105ES is square‑body fast‑acting aR‑class DC fuse for 1500Vdc new‑energy & energy‑storage systems, rated current from 400A‑2000A. It features 50kA high interrupting capacity, low arc‑voltage & low energy let‑through I²t, UL248‑13 & IEC60269‑4 compliant. Widely deployed for energy‑storage containers,battery packs,wind‑power equipment and DC‑drive short‑circuit & over‑current protection.

Main Electrical Ratings & Key Specifications

ItemParameter
Product Series ModelGFEVT1500‑S‑105ES
Rated Voltage1500 Vdc
Rated Current Range400A ~ 2000A , Size 4#
Interrupting Capacity50kA@1500Vdc (L/R ≤15ms)
Fuse ClassaR (partial‑range semiconductor protection)
Minimum Breaking Current>3 In
CharacteristicFast‑Acting High‑Speed DC Fuse, low I²t let‑through
Certifications & StandardsUL248‑13, IEC 60269‑4, RoHS Compliant; REACH statement upon request
Operating Temperature‑40℃ ~ +85℃; Standard working:‑5℃ ~ +40℃
Mounting2pcs M12 bolts; Hole max depth 12.5mm, min thread‑length:12mm; Tin‑plated 3‑5μm
Typical ApplicationEnergy‑storage ESS,battery‑pack,wind‑power,DC‑drive system short‑circuit protection

Complete Model List | Melting / Clearing I²t & Power‑Loss Data

Part NumberRated AmpsSizeMelting A²s @50kAClearing A²s @50kAPower Loss(W)
GFEVT1500‑400S‑105ES400A4#25,840136,400198
GFEVT1500‑500S‑105ES500A4#57,350275,430200
GFEVT1500‑630S‑105ES630A4#117,640563,500232
GFEVT1500‑700S‑105ES700A4#164,320783,000249
GFEVT1500‑800S‑105ES800A4#242,1001,160,250256
GFEVT1500‑900S‑105ES900A4#345,7001,668,800277
GFEVT1500‑1000S‑105ES1000A4#470,5002,290,100293
GFEVT1500‑1100S‑105ES1100A4#625,2003,005,000312
GFEVT1500‑1200S‑105ES1200A4#752,5003,600,200320
GFEVT1500‑1250S‑105ES1250A4#915,2004,430,000325
GFEVT1500‑1300S‑105ES1300A4#1,005,5005,230,500338
GFEVT1500‑1350S‑105ES1350A4#1,290,0006,245,000348
GFEVT1500‑1400S‑105ES1400A4#1,350,9006,980,500354
GFEVT1500‑1500S‑105ES1500A4#1,580,5607,630,000362
GFEVT1500‑1600S‑105ES1600A4#1,940,5009,295,950375
GFEVT1500‑1800S‑105ES1800A4#2,728,60013,120,650394
GFEVT1500‑2000S‑105ES2000A4#3,300,98018,560,370412

Mechanical Dimension

Square‑body construction, overall dimension 153±3 mm × 105±1.5 mm. 2‑pcs M12 mounting holes; max hole‑depth:12.5 mm, minimum thread‑length 12 mm. Terminals tin‑plated 3‑5 microns. Please check dimension drawing for full mechanical specifications.

Derating & Installation Instructions

  • Recommended continuous operating current ≤ 75% of fuse rated‑current under standard‑5℃~40℃ ambient environment.
  • For ambient temperature above 40℃, apply temperature‑derating factor Kt. For closed‑cabinet installation at altitude 2000‑4500 m, apply altitude‑derating Ka: derate 2‑5% per 1000‑meter elevation; open‑air deployment normally ignores altitude‑derating.
  • Support vertical, horizontal and inclined mounting. Avoid gravity and vibration side‑effects for spring‑contact structures.
  • Terminal contact resistance shall be kept low to prevent extra over‑heating and power‑loss rise.

Typical Applications

  • Energy‑storage ESS container & DC main‑circuit protection
  • Large‑capacity battery‑pack short‑circuit protection
  • Wind‑power converter DC‑side protection
  • DC drives and other 1500Vdc new‑energy power‑equipment over‑current & short‑circuit protection

Download Datasheet

GFHVT1500-S-105ES-Series.-400-2000A-1500Vdc-IR-50kA-4-Fast-Acting-fuse

Frequently Asked Questions

What is rated voltage of GFEVT1500‑S‑105ES series?
This high‑speed fuse is rated for 1500Vdc, designed for DC‑only new‑energy & energy‑storage circuits, not intended for AC‑system usage.

 

What current ratings are available?
400A,500A,630A,700A,800A,900A,1000A,1100A,1200A,1250A,1300A,1350A,1400A,1500A,1600A,1800A,2000A (Size 4#).

 

What is its interrupting capacity and fuse class?
Interrupting capacity:50kA@1500Vdc(L/R ≤15ms); fuse class aR; minimum breaking current>3 In.

 

What standards and certifications apply?
Designed per UL248‑13 & IEC 60269‑4; RoHS‑compliant; REACH declaration can be supplied upon request.

 

What is the rule for continuous‑current selection?
Keep continuous working current ≤ 75% of fuse rated‑ampere under‑5℃~40℃ standard ambient.

 

Must I derate for high‑temperature or high‑altitude?
Yes. Above 40℃ apply temperature‑derating Kt. For closed‑box installation 2000‑4500 m altitude derate 2‑5% /1000 m; open‑air application generally skips altitude‑derating.

 

Can I install this fuse horizontally or inclined?
Vertical, horizontal and inclined mounting are allowed. Prevent gravity and vibration from degrading spring‑contact electrical connections.

 

What are main target‑applications?
ESS energy‑storage systems, battery‑pack, wind‑power converters,DC‑drives and other 1500Vdc new‑energy power‑equipment short‑circuit protection.

 

Can I replace the fuse under live‑load?
Do NOT replace fuse while carrying live‑load unless a matched fuse‑disconnector switch assembly is implemented.

 

What are the storage conditions?
Store in original package:‑40℃~+85℃, RH ≤70% at 40℃, dust‑free warehouse environment.