GFPVT1000‑10R series photovoltaic pv fuse 1000VDC 10‑35A, gPV solar string protection

카테고리:
GFPVT1000‑10R series photovoltaic pv fuse, 1000VDC 10‑35A, 30kA breaking capacity, RoHS compliant, for solar photovoltaic string over‑current short‑circuit protection.

제품 선택

귀하의 용도에 적합한 퓨즈를 찾는 데 도움을 드립니다.

기술 지원

제품 상세 정보 및 기술 지원이 필요하시면 저희 팀에 문의하십시오.

프로젝트 문의

필요사항, 수량 및 구매 계획에 대해 논의하십시오.

프로젝트에 필요한 퓨즈가 필요하신가요?

제품 안내 및 견적을 위해 필요한 사항을 알려주세요.



치수(mm)

Ferrule xxA-10R Dimensions

GFPVT1000‑10R series photovoltaic pv fuse 1000VDC 10‑35A

GFPVT1000‑10R series photovoltaic pv fuse 1000VDC 10‑35A is a gPV‑type solar photovoltaic fuse designed for PV string over‑current and short‑circuit protection. It delivers excellent DC interruption performance, low I²t value and low power loss. Supports ferrule‑type and axial bolt‑on mounting styles, complies with UL‑248‑19 & IEC 60269‑1/6 standards. Ideal for solar harness, combiner box and inverter DC‑side circuits.

GFPVT1038-35A-Photovoltaic-Fuses

주요 특징

  • Model Series: GFPVT1000‑10R photovoltaic pv fuse
  • Rated Voltage: 1000VDC
  • Current Range: 10A‑35A
  • Breaking Capacity: Max 30kA @1000VDC; Min 135% In
  • Time Constant: ≤2±0.5 ms
  • Low I²t value, low voltage drop & low power loss
  • Excellent DC fault‑current interruption capability
  • Two terminal versions: Ferrule‑type(xxA‑10R), Axial bolt‑on(xxAP‑10R)
  • Able to interrupt low over‑current faults from defective PV strings
  • Compliant: UL‑248‑19, IEC 60269‑1/6, RoHS, REACH available on request
  • Axial bolt‑on mounting torque: M5 bolt 4.5±1.0 N·m
  • High vibration resistance ≥20g for outdoor solar equipment

General Technical Specifications

Product SeriesGFPVT1000‑10R Photovoltaic PV Fuse
정격 전압1000 V DC
정격 전류 범위10A‑35A
Max Breaking Capacity30kA @1000VDC
Minimum Breaking Capacity135% In
Time Constant≤2±0.5 ms
Terminal VersionsFerrule‑type (‑A‑10R), Axial bolt‑on (‑AP‑10R)
Bolt‑on Torque(M5)4.5±1.0 N·m
Standards ComplianceUL‑248‑19, IEC 60269‑1/6, RoHS
Vibration Resistance≥20g
작동 온도‑5℃ ~ +40℃(regular);‑40℃~+125℃(allowable)

Part Number List & Electrical Parameters

부품 번호정격 전류Melting A²sClearing A²sPower Loss‑80%In(W)Power Loss‑100%In(W)
GFPVT1000‑10A‑10R /‑AP‑10R10A21011751.11.5
GFPVT1000‑12A‑10R /‑AP‑10R12A25214051.31.7
GFPVT1000‑15A‑10R /‑AP‑10R15A31517571.62.3
GFPVT1000‑16A‑10R /‑AP‑10R16A32617801.62.3
GFPVT1000‑20A‑10R /‑AP‑10R20A42023402.12.9
GFPVT1000‑25A‑10R /‑AP‑10R25A52529292.73.5
GFPVT1000‑30A‑10R /‑AP‑10R30A63035153.24.2
GFPVT1000‑32A‑10R /‑AP‑10R32A89039954.05.3
GFPVT1000‑35A‑10R /‑AP‑10R35A97545454.66.2

응용 시나리오

GFPVT1000‑10R series photovoltaic pv fuse 1000VDC 10‑35A is widely applied for grid‑tied & off‑grid solar‑power systems: PV combiner boxes, solar inverter DC input side, photovoltaic string harness, energy‑storage DC circuits. It provides reliable gPV‑class over‑current & short‑circuit protection for solar modules and wiring.

Installation & Operating Notes

  • Two terminal styles: ferrule‑end for fuse‑clip mounting; axial bolt‑on for screw fastening; apply 4.5±1.0 N·m torque for M5 bolt terminals.
  • Recommended continuous operating current ≤75% of fuse rated‑current; apply temperature derating factor when ambient temperature exceeds 40℃.
  • Can be insulated by over‑molding or heat‑shrink tubing for wire‑harness integration.
  • Do NOT replace fuse under loaded DC circuit conditions unless specially‑designed switchgear is fitted.
  • Replace fuse immediately if mechanical damage or housing crack is observed.
  • For high‑vibration outdoor installations, perform extra reliability validation tests as required.

Packing & Supply

Standard bulk package. Sample testing support, OEM customization, stable mass‑volume supply for solar‑energy equipment manufacturers. REACH declaration available upon customer request.

자주 묻는 질문

Q: What voltage & current for GFPVT1000‑10R series photovoltaic pv fuse 1000VDC 10‑35A?
A: Rated 1000VDC, current range 10A‑35A, max breaking capacity up to 30kA@1000VDC.

Q: What standards does GFPVT1000‑10R comply with?
A: Designed according to UL‑248‑19, IEC 60269‑1/6, RoHS compliant, REACH document available on request.

Q: What mounting types are available?
A: Ferrule‑type (‑A‑10R) for fuse‑clip; axial bolt‑on (‑AP‑10R) for bolt fastening(M5 torque:4.5±1.0N·m).

Q: Where to use GFPVT1000‑10R pv fuse?
A: Solar PV combiner box, inverter DC‑side, photovoltaic string harness and off‑grid solar DC‑system protection.