High-Speed Fuses GFEVT1500‑159E 1400‑3000A 1500VDC Fuse
GFEVT1500‑159E square high-speed 1500Vdc fuse, 1400‑3000A fast-acting DC fuse, 250kA interrupt rating, UL248-13 listed for energy storage, ESS and battery pack short circuit protection.
Need a Fuse for Your Project?
Share your requirements with us for product guidance and a quotation.
Dimensions (mm)

GFEVT1500‑159E Square High‑Speed Fuses 1400‑3000A 1500VDC Fast‑Acting New‑Energy Fuse
Our High-Speed Fuses model GFEVT1500‑159E is a square fast-acting DC fuse rated 1500Vdc, covering 1400A to 3000A. This high-speed fuse provides 250kA high interrupting capacity, UL248-13 certified, widely used for energy storage ESS containers, large battery packs and new energy DC overcurrent & short circuit protection.
GFEVT1500‑159E series square‑body high‑speed fast‑acting DC fuses are engineered for 1500Vdc new‑energy power systems with rated current from 1400A‑3000A. Excellent DC interrupting performance provides reliable short‑circuit protection for energy storage containers, battery packs, DC combiner cabinets and power converters. UL 248‑13 listed and RoHS compliant, superior cycling capability for heavy‑duty DC working conditions.
Main Electrical Ratings & Key Specifications
| Item | Parameter |
|---|---|
| Rated Voltage | 1500 Vdc |
| Rated Current Range | 1400A ~ 3000A |
| Interrupting Capacity | 250kA@1500Vdc (L/R ≤5ms) 100kA@1500Vdc (L/R ≤15ms) |
| Fuse Characteristic | Fast‑Acting High‑Speed DC Fuse |
| Certifications | UL248‑13 Listed, RoHS Compliant, REACH statement upon request |
| Operating Temperature | ‑40℃ ~ +85℃; Standard working:‑5℃ ~ +40℃ |
| Storage Condition | ‑40℃ ~ +85℃; RH ≤70% @40℃ |
| Mounting Requirement | 5 pcs M12 screws each side; Nut torque: 35±4% N·m |
| Application Scenarios | Energy Storage ESS, Battery Pack, DC Converter, New‑Energy Power Equipment Short‑circuit Protection |
Model List | Pre‑Arcing I²t & Power Loss Data
| Part Number | Rated Amps | Pre‑Arcing I²t(A²s) | Max Operating I²t(A²s) | Power Loss(W) | Compliance |
|---|---|---|---|---|---|
| GFEVT1500‑1400A‑159E | 1400A | 833,250 | 3,024,000 | 350 | RoHS |
| GFEVT1500‑1500A‑159E | 1500A | 1,078,000 | 3,759,500 | 370 | RoHS |
| GFEVT1500‑1600A‑159E | 1600A | 1,325,700 | 5,435,000 | 420 | RoHS |
| GFEVT1500‑1800A‑159E | 1800A | 1,980,000 | 5,750,000 | 460 | RoHS |
| GFEVT1500‑2000A‑159E | 2000A | 2,530,000 | 7,910,000 | 475 | RoHS |
| GFEVT1500‑2500A‑159E | 2500A | 4,696,500 | 14,294,000 | 520 | RoHS |
| GFEVT1500‑3000A‑159E | 3000A | 8,505,000 | 25,029,000 | 590 | RoHS |
Mechanical Dimension
Square housing structure, nominal width 159mm, max 163mm. Each side fitted with 5pcs M12 mounting holes; Hole max depth:13mm, minimum thread length:10mm. Terminals tin‑plated 3‑5μm. Refer to dimension drawing for full mechanical dimension details.
Derating & Installation Instructions
- Recommended continuous working current ≤75% of fuse rated‑current under standard environment.
- When ambient temperature higher than 40℃, apply temperature derating factor Kt. For closed cabinet high‑altitude installation 2000‑4500m, apply altitude factor Ka, derate 2‑5% per 1000‑meter elevation.
- M12 mounting nut recommended tightening torque: 35±4% N·m.
- Support vertical, horizontal and inclined installation; prevent gravity and vibration influence for spring‑contact assembly.
Typical Applications
- Energy‑storage container & ESS DC main circuit protection
- Large‑capacity battery pack short‑circuit protection
- 1500Vdc power converter over‑current protection
- New‑energy power station high‑current DC protection
Download Datasheet
GFHVT1500-159E-Series.-1400-3000A-1500Vdc-Fast-Acting-Fuse-1
Frequently Asked Questions
- What is the rated voltage of GFEVT1500‑159E series fuse?
- This series is rated for 1500Vdc, designed exclusively for DC new‑energy systems, not recommended for AC application.
- What current range does GFEVT1500‑159E cover?
- Available rated current: 1400A,1500A,1600A,1800A,2000A,2500A,3000A.
- What is the interrupting capacity?
- 250kA@1500Vdc (L/R ≤5ms); 100kA@1500Vdc (L/R ≤15ms).
- What certifications does this fuse have?
- UL Listed to UL248‑13 standard, RoHS compliant. REACH declaration available upon customer request.
- What continuous current should I use for selection?
- General rule: continuous operating current ≤ 75% of fuse rated current under standard ‑5℃~40℃ ambient condition.
- Do I need derating for high‑temperature or high‑altitude installation?
- Yes. Above 40℃ ambient temperature needs temperature derating factor Kt. For closed‑box installation between 2000‑4500 m altitude, derate rated‑current 2‑5% per 1000 m rise. Open‑air installation can ignore altitude influence generally.
- What is the correct tightening torque for M12 mounting screws?
- Recommended nut tightening torque: 35±4% N·m. Improper torque will cause overheating and higher power loss.
- Can this fuse be installed horizontally or vertically?
- Yes, supports vertical, horizontal and inclined mounting. Avoid gravity & vibration impact for spring‑contact connections.
- What applications fit for GFEVT1500‑159E high‑speed fuse?
- Energy storage ESS container, large battery pack, DC combiner cabinet, 1500Vdc converter, new‑energy power station DC short‑circuit & over‑current protection.
- Can I replace the fuse under load condition?
- NOT recommended. Do not replace fuse with live‑load unless matched fuse‑disconnector switch assembly is applied.
- What is storage requirement?
- Store in original package: ‑40℃ ~ +85℃, max RH 70% at 40℃, dust‑free warehouse environment.