Ceramic Car Fuse, ANL Mega Bolt Down Fuses for Automotive DC Circuits

Ceramic car fuse ANL mega bolt down fuses for automotive circuits, ISO20934 short‑circuit‑only protector 80A‑500A 100‑125V DC, M8 51 mm bolt mounting.

Product Selection

Support in finding suitable fuses for your application.

Hỗ trợ kỹ thuật

Contact our team for product details and technical guidance.

Project Enquiries

Discuss your requirements, quantities, and purchasing plans.

Need a Fuse for Your Project?

Share your requirements with us for product guidance and a quotation.

Dimensions (mm)
Dimensions

Ceramic car fuse anl mega bolt down fuses for automotive circuits are heavy‑duty high‑current DC protective devices manufactured to ISO 20934 Special Purpose Fuses standard. This ANL‑style mega bolt‑down fuse adopts high‑temperature‑resistant ceramic housing and tin‑plated copper‑alloy terminals with dual M8 mounting bolts on 51 mm centre‑to‑centre spacing. Important warning: This is a short‑circuit‑only protector and CANNOT provide overload‑protection. Designed for 100‑125V DC heavy‑current automotive‑grade circuits, widely used for electric vehicles, RV, marine vessels and energy‑storage battery bank short‑circuit protection.

Core Features

  • High‑temperature resistant ceramic shell, stable performance for vehicle harsh thermal & vibration environments
  • Tin‑plated copper‑alloy terminals; dual M8 bolt holes with 51 mm hole centre‑to‑centre distance
  • Recommended mounting torque: 12.0 Nm ±1 Nm to guarantee stable heavy‑current contact performance
  • Rated breaking capacity: 100V‑125V DC; purely short‑circuit protector, no overload‑protection capability
  • Conforms to ISO 20934 Special Purpose Fuses international specification
  • Operating temperature: ‑40℃ ~ +125℃; maximum allowable contact‑point temperature reaches 150℃
  • Wide current selection 80A‑500A for automotive and energy‑storage main‑battery short‑circuit protection

General Specifications

ItemParameter
Shell MaterialCeramic high temperature resistant
TerminalCopper alloy, tin‑plated, 2 x M8 bolts, 51 mm hole centre distance
Mounting Torque12.0 Nm ±1 Nm
Breaking Capacity100V‑125V DC
Compliance StandardISO 20934 Special Purpose Fuses
Operating Temperature Range‑40℃ ~ +125℃; Max contact‑point temperature: 150℃
Device TypeShort‑circuit protector only (without overload‑protection)

Time‑Current Characteristics

% of Rated Current80A‑250A Min / Max(s)300A‑500A Min / Max(s)
75%‑ / ‑‑ / 14400 s
100%14400 s / ‑‑ / ‑
135%120 s / 1800 s‑ / ‑
200%1 s / 15 s1 s / 15 s
350%0.300 s / 5 s0.500 s / 5 s
600%0.100 s / 1 s0.100 s / 1 s

Electrical Ratings & Typical Voltage Drop

Internal Model No.Rated Current(A)Typ Voltage Drop
ANL‑B100B08080A≤110 mV
ANL‑B100B100100A≤110 mV
ANL‑B100B125125A≤110 mV
ANL‑B100B150150A≤110 mV
ANL‑B100B175175A≤110 mV
ANL‑B100B200200A≤110 mV
ANL‑B100B225225A≤110 mV
ANL‑B100B250250A≤80 mV
ANL‑B100B275275A≤80 mV
ANL‑B100B300300A≤80 mV
ANL‑B100B350350A≤80 mV
ANL‑B100B400400A≤80 mV
ANL‑B100B450450A≤80 mV
ANL‑B100B500500A≤80 mV

Typical Application Scenarios

  • 100‑125V DC new‑energy vehicle main‑battery short‑circuit protection
  • RV, yacht and marine vessel high‑capacity battery‑bank DC‑system protection
  • Heavy‑duty special‑vehicle and mobile‑equipment power‑distribution circuits
  • Off‑grid & on‑grid energy‑storage DC main‑circuit short‑circuit protection

Match this ceramic car fuse anl mega bolt down fuses for automotive circuits with our bolt‑down fuse holders for complete power‑distribution assembly.

Installation & Safety Notes

  • This is short‑circuit‑only protector and cannot provide overload‑protection function.
  • Disconnect main power before installation or replacement to avoid accidental short‑circuit risk.
  • Follow mounting torque 12.0 Nm ±1 Nm; loose contact will result in abnormal over‑heating under heavy‑current load.
  • Temperature derating assessment is required for enclosed high‑temperature installation compartments.
  • Only replace with same‑specification protector to maintain original circuit‑protection performance.

Câu hỏi thường gặp

Q: What is ceramic car fuse anl mega bolt down fuses for automotive circuits?
A: Ceramic car fuse anl mega bolt down fuses for automotive circuits is ISO20934‑compliant ANL‑style bolt‑mount DC protective component with high‑temperature ceramic housing. It is designed for 100‑125V DC heavy‑current short‑circuit protection for EV, marine and energy‑storage systems.

Q: Does this fuse provide overload protection?
A: No. It is short‑circuit‑only protector and offers zero overload‑protection capability.

Q: What are the mounting requirements?
A: Dual M8 bolt holes with 51 mm centre‑distance; recommended tightening torque:12.0 Nm ±1 Nm.

Q: Which standard does this product follow?
A: Complies with ISO 20934 Special Purpose Fuses standard.

Q: What ampere ratings are available?
A: Available ratings:80A,100A,125A,150A,175A,200A,225A,250A,275A,300A,350A,400A,450A,500A.

Q: What is its rated breaking capacity?
A: Rated breaking capacity is 100V‑125V DC.

Request Quotation & Technical Support